Manual
Power Quality Analysis Software
WebPQ®
WebPQ displayed on smartphone, desktop monitor, and laptop

Note: Please note that this user manual may not always reflect the current state of the software version. With software updates, it may happen that the present description is no longer accurate in some points. In this case, please contact us directly or use the current version of the user manual, which you can find on our website www.a-eberle.de.

Publisher:

A. Eberle GmbH & Co. KG Frankenstraße 160
D-90461 Nuremberg

Phone: +49 911 62 81 08 0
Fax: +49 911 62 81 08 99
Email: info@a-eberle.de
Internet: www.a-eberle.de

The company A. Eberle GmbH & Co. KG assumes no liability for damages or losses of any kind resulting from printing errors or changes in this user manual.

Likewise, the company A. Eberle GmbH & Co. KG assumes no liability for damages and losses of any kind resulting from the use of the software or from devices modified by the user through the software.

Copyright 2025 A. Eberle GmbH & Co. KG. All rights reserved.


Table of Contents


1. User Guidance

The user manual summarizes all important information for installation and operation. Read the user manual completely and only use the product once you have understood the user manual.

1.1. Target Audience

This user manual is intended for trained professionals as well as trained and certified operating personnel. The content of this user manual must be made accessible to the persons responsible for the installation and operation of the system.

1.2. Warnings

Warnings are structured as follows:

Type and source of danger!
DangerConsequences of non-compliance.
Signal wordMeasureMeasure to avoid the danger.

Warnings differ according to the type of danger as follows:

DangerWarns of an imminent danger that will result in death or serious injury if not avoided.
Danger
WarningWarns of a potentially dangerous situation that will result in moderate or minor injury if not avoided.
Warning
CautionWarns of an imminent danger that will result in death or serious injury if not avoided.
Caution
NoteWarns of a potentially dangerous situation that will result in property or environmental damage if not avoided.
Note

1.3. Tips

NoteTips for proper handling of the software and recommendations.
Note

1.4. Other Symbols

Structure of bulleted lists:

Structure of numbered lists:

  1. Level 1

  2. Level 1

    1. Level 2

    2. Level 2

1.5. Applicable Documents

For the safe and correct use of the software, also observe the additionally supplied documents as well as relevant standards and laws.

1.6. Storage

Keep the user manual, including the applicable documents, readily available near the system.


2. Scope of Delivery, Order Features, and System Requirements

2.1. Scope of Delivery


2.2. Order Features

WebPQ® database software including PostgreSQL database for fully automated processing and evaluation of power quality data in your IT environment! Basic versions always include 3 units – unlimited expansion possible via add-ons.

2.2.1. Functionality

2.2.2. Licenses

License TypeDescriptionArticle Number
WebPQ Basicincl. 3 units for up to 30 units with basic functionalityL.900.9266.10
WebPQ Professionalincl. 3 units for up to 100 units with professional functionalityL.900.9266.20
WebPQ Enterpriseincl. 3 units for systems > 100 units with enterprise functionalityL.900.9266.30

WebPQ Initial Order - Number of Units

Number of UnitsArticle Number
10 UnitsL.900.9266.1010
30 UnitsL.900.9266.1025
50 UnitsL.900.9266.2050
100 UnitsL.900.9266.2100
500 UnitsL.900.9266.3500
1000 UnitsL.900.9266.3599

Available WebPQ Add-ons

Add-on NameArticle Number
WebPQ Add-on "Fleet Management"L.900.9265.32
WebPQ Add-on "Nequal Export"L.900.9265.34

Additional Units

Number of UnitsArticle Number
WebPQ Add-on 10 UnitsL.900.9266.60
WebPQ Add-on 50 UnitsL.900.9266.61
WebPQ Add-on 100 UnitsL.900.9266.62

Maintenance Agreements

Maintenance AgreementArticle Number
WebPQ Maintenance Agreement AnnualL.900.9066.10.01
WebPQ Maintenance Agreement One-timeL.900.9066.10.02

2.3. System Requirements

WebPQ displayed on smartphone, desktop monitor, and laptop
**Note:** The following pages contain the system requirements for the WebPQ software. Please note that these requirements may not always reflect the current state of the software version. With software updates, it may happen that the present description is no longer accurate in some points. In this case, please contact us directly or use the current version of the system requirements, which you can find on our website [www.a-eberle.de](http://www.a-eberle.de).

Publisher:
A. Eberle GmbH & Co. KG Frankenstraße 160 D-90461 Nuremberg


2.3.1. Supported Operating Systems & Browsers

2.3.2. Supported Database Systems

*PostgreSQL is supported from WinPQ > 6.2. **Individual order process and license key are necessary! Consultation required.

2.3.2.1. Special Database Settings

2.3.2.1.1. Database Settings / Special Considerations for Microsoft SQL

If WebPQ is to be operated with MS-SQL, the MS-SQL server must be configured to support Mixed-Mode Authentication. This is necessary so that WebPQ can access the database. Alternatively, a Windows user with appropriate permissions can be used for database access. This user must then be stored as a user in the WebPQ service.


2.3.3. Minimum System Requirements

2.3.4. Recommended System Configuration

2.3.5. Operation in a Terminal Server Environment

Running WebPQ in a terminal server environment is technically possible, but generally not required, as WebPQ is provided as a web application via an integrated web server. Installation is performed directly on the terminal server; the configuration directory is stored by default in the system folder %programdata%.

Administration Notes:

Optional non-administrative service and operator accounts:

Administrators-only service IPC is the default and recommended configuration. An installer-provisioned configured-principals mode can instead run the service under a limited domain account and authorize one dedicated operator group to use the backend administration application without UAC. The installer must configure the account SIDs and the required registry and data-directory permissions; manually widening the token directory to Users or Everyone is unsupported and removes the authorization boundary.

Membership in that operator group grants full control of the WebPQ installation, including writing settings and secrets, controlling backend availability, and creating process-memory dumps that can contain secrets. Keep the group dedicated, narrowly assigned, and managed with the same care as an administrative role. This explicit authorization is not itself a CVSS-scored vulnerability (CVSS: N/A); assigning an untrusted or broad local group recreates a local privilege-escalation path into the service account (CVSS 3.1: 6.8).

User Access Model:

Technical Recommendations:

2.3.6. Recommended Tools

2.3.7. Recommended Certificates

2.3.7.1. Information about the SSL certificate of the WebPQ web server

For productive operation, the web interface should be provided via HTTPS only. If the WebPQ web server performs TLS termination itself, this requires a certificate matching the hostname in use together with the corresponding private key in PEM format.

The certificate should come from a trusted PKI that fits the target operating environment. Validity, renewal, and secure storage of the private key must be ensured by the operator as part of normal certificate management.


2.3.8. Typical System Configuration / System Diagram / Terminology

Diagram of a typical WebPQ system configuration with server, client, database, measuring devices, NTP server, and SMTP server

Required Port Numbers for Communication:

Releases in gateways and firewalls must be configured from row to column (e.g., from the WebPQ Client, port 8443 - HTTPS must be enabled to the server to allow data usage on the client).

WebPQ ServerWebPQ ClientDatabase ServerPQI-D (REG-COM)PQI-DA smart / PQI-DE / PQI-LVNTP ServerSMTP ServerWebserver of Device PQI-DA smart / PQI-DE / PQI-LV
WebPQ Serverxx5432 PostGre, 3306 MySQL8000 TCP, 1111 TCP5040 TCP-CCCI, 22 SSH123 NTP587 STARTTLS, 465 SSL/TLS8443 HTTPS
WebPQ Client8443 HTTPS, 1701 … 170X ParaPQIDxxxxxxx
Database Serverxxxxxxxx
PQI-D (REG-COM)xxxxxxxx
PQI-DA smart / PQI-DE / PQI-LVxxxxx123 NTPxx
NTP Serverxxxxxxxxx
SMTP Serverxxxxxxxx
Webserver of Device PQI-DA smart / PQI-DE / PQI-LVxxxxxxxx

* 1701...170X: Range for specific ports for PQI-Ds, depending on configuration.

Typical Data Volumes in Communication

Connecting a measuring device to the WebPQ database generates approximately 20 MB per week in the standard configuration. Since the readout process is continuous, the data transfer requires a minimum speed of only 200 kbit/s.

Additional Windows Requirement for PQI-D(A) Parameterization

For parameterizing PQI-D(A) measuring devices through the WebPQ Server, the Windows users executing the workflow must be allowed to run applications.

If application execution is restricted by group policy, at least the following exceptions must be configured:

Additional Requirements for Backup and Restore

The Backup section of the administration interface and the WebPqMigrationTool command line tool use the same PowerShell engine for preflight, backup, restore, and automated backups. The complete workflow is described under WebPQ Migration Tool; in addition, the following requirements apply:

Automated Backup to a Network Share

If access through the computer account is not possible or not desired, the WebPQ Automated Backup Windows task can afterwards be switched to a user account with network access in the Task Scheduler. That account must meet the following conditions:

If the automated backup is set up again in the administration interface, for example after changing the time or the target path, the task is overwritten and runs under the SYSTEM account again. The switch to the user account must then be repeated.
Note

2.3.9. Customer Checklist – System Information & Requirements

The following checklist is used to collect system information and requirements for the WebPQ installation to ensure smooth and fast service. Please fill in the relevant fields and send the completed checklist to your contact at A. Eberle.

2.3.9.1. WinPQ Information

2.3.9.2. General Database Information

2.3.9.3. General Device Information

Note: The sum of devices and users determines the required number of units for WebPQ. If you have any questions, please contact your A. Eberle representative.


2.3.9.4. General Server Information

2.3.9.5. General Service Information


3. Safety Instructions

The following notes describe general basics for secure WebPQ operation. The complete administrative IT security review is intentionally documented in a separate handbook that is provided separately on request.

3.1. General Notes

For information on patch management and for the separate WebPQ IT security documentation, please contact your sales partner or support.
Note

4. Intended Use

The product WebPQ is exclusively used for the evaluation of Power Quality measurement data and energy measurement data in the power grid at low, medium, and high voltage levels. If the software is used in a manner not specified by the manufacturer, it may potentially cause damage!


5. Installation

The installation of WebPQ is carried out in several steps, including installation, administrative configuration, and initial setup. As of 2025, with WebPQ taking over many functions from WinPQ, various installation options and operating modes are available.

5.1. Installation and Operation of WebPQ as a Standalone Version

This option is suitable if the basic functions of WebPQ, which continue to evolve, are sufficient and there are no special requirements for export formats or integration of devices from the classic platform (PQI-D / PQI-DA).

Secure operation requires that this installation handbook is used together with the separate WebPQ IT security documentation. That separate document is provided for administrative and organizational security review.

5.2. Operating WinPQ Software parallel to WebPQ

WinPQ software is always included in the license and delivery of WebPQ software and can be selected or deselected during installation.

A separate uninstallation assistant is available for uninstalling WinPQ software, which is described here.

Please make sure to check the compatibility information and versions of the supported databases in the chapter System Requirements
Hint

5.3. Activation of WebPQ via Activation Key

Starting with WebPQ version 2.1 the installation must be activated with an Activation Key. Until activation a notice dialog or the activation window is shown at the top. The software can be used for a maximum of 30 days without activation; within this period the Activation Key must be applied.

Dialog for activating the WebPQ installation with an activation key

The activation file is generated using the hardware ID of the host and is only valid on this host. No direct internet connection is required for activation, but you must transfer a file from the host to another PC with internet access to activate the key at https://activate-license.powerquality.cloud/.

If the host hardware changes later, the stored activation is no longer valid and the activation process must be repeated. In that case, support may first need to reset the previous activation.

Proceed as follows:

  1. Download the file LicenseActivationRequest.json via the button Save to file or copy its content via the button Copy to clipboard.

  2. Open https://activate-license.powerquality.cloud/ and submit the activation request (either upload the file or paste the copied content).

  3. After successful activation you receive an activation token for the license. Copy this token and paste it into the field to activate the installation, or alternatively use the file selection dialog to choose the activation file you downloaded from the activation page.

If you plan a system migration or the host hardware changes, a new activation is required. Repeat the process described above. For questions contact our support at pqsys-support@a-eberle.de.

For later license replacement, renewal, or reactivation details inside the running application, see the License Management chapter.


5.4. Installation variants

  1. WebPQ Installation with Database (PostgreSQL) - Standard Case

    The PostgreSQL database is installed directly on the host along with the WebPQ application. This installation type is particularly recommended for small to medium-sized systems (up to 200 devices). The PostgreSQL database is also installed during setup. Individual directory structures can be adjusted during installation.

  2. WebPQ Installation Without Database and Connection to an Existing Database or Installation of a PostgreSQL Database on a Dedicated Server

    This option is suitable if an existing database infrastructure is to be used or if the PostgreSQL database is installed on a separate server.

  3. WebPQ Installation with Parallel WinPQ Installation with or Without a Database

    This installation type should be selected if WinPQ software functions need to be retained. It must be decided which instance (WinPQ or WebPQ) will handle communication with the devices.


5.5. Installation

The WebPQ software is delivered securely via our portal https://software.a-eberle.de using a dedicated one-time access with SHA256 hash sum verification. Please verify the checksum for security purposes.

Secure installation also includes reviewing the intended target architecture, communication paths, permission model, and the requirements described in the separate WebPQ IT security documentation.

5.5.1. Start and Language Selection

The installation process starts by double-clicking the "WebPQ_Setup_x.y.z.exe" file. The installation must be confirmed in the User Account Control with "YES." Next, a language selection for the assistant must be made.

Installation assistant with language selection

5.5.2. License Agreement

Acceptance of the license terms is required. More details on the terms and maintenance contract can be found in the delivery documents.

License agreement in the installation assistant

5.5.3. Target Directory

A target directory for installation can be specified. All necessary operational data will be stored in this directory. User-specific data can be found in %programdata%/aeberle/webpq.

Installation assistant with target directory selection

5.5.4. License File

A license file is required for the software to operate. This JSON-format file is provided during initial delivery or with a maintenance contract. The JSON file can be selected via "Browse" and is validated by the assistant. If the file is lost, please contact A. Eberle with your order and customer number.

Installation assistant with license file selection

5.5.5. Selecting WinPQ

If the WinPQ software is to be installed, it must be selected here. Information on why this might be necessary can be found under Operating WinPQ Software Parallel to WebPQ.

Installation assistant with WinPQ selection

5.5.6. Database Installation

The appropriate mode must be selected based on the Installation Variants.

Installation assistant with database installation selection

In this mode, the following steps are performed:

The default passwords should always be changed to avoid significant security risks. It is recommended to use the advanced installation to set custom passwords.
Note

5.5.6.1. Advanced PostgreSQL Installation (Recommended)

In this mode, PostgreSQL is installed with custom settings:

Installation assistant for advanced PostgreSQL installation

5.5.6.2. Installation Without PostgreSQL

This mode is suitable if an existing database is used, either running on another server or already available on the host. After completing the assistant, the following connection details must be available. Pay attention to case sensitivity in parameter names!


5.6. PostgreSQL Backup Mirror with Streaming Replication

For installations with a dedicated PostgreSQL server, an additional continuously updated backup mirror can be set up. In this setup, a second PostgreSQL server runs as a replica of the production system.

5.6.1. Backup Philosophy

A replication server increases resilience, but it does not replace a classic backup strategy.

The recommended setup is therefore a combination of:

Replication helps protect against server or hardware failure. Classic backups additionally protect against operator errors, logical data errors, and accidental deletion of data that would otherwise also be replicated.

5.6.2. Prerequisites

You need:

5.6.3. Goal

The backup server is a continuously updated copy of the primary server. Changes from the production system are transferred automatically. During normal operation, the backup server is read-only.

5.6.4. Simplified Overview

Server A = Primary server / production system
    -> WebPQ application
    -> PostgreSQL primary database
    -> active write operations

Server B = Backup server / mirror
    -> PostgreSQL replica
    -> continuous transfer of changes from Server A
    -> read-only operation during normal use

5.6.5. Step 1: Prepare the Primary Server

On the primary server, open the file postgresql.conf and set at least the following values:

wal_level = replica
max_wal_senders = 5

Then open the file pg_hba.conf and allow replication access for the backup server or the corresponding network. Example:

host replication replicator 192.168.1.0/24 md5

Then create a user for replication:

CREATE ROLE replicator WITH REPLICATION LOGIN PASSWORD 'password';

Restart PostgreSQL on the primary server afterward.

5.6.6. Step 2: Set Up the Backup Server

Stop PostgreSQL on the backup server.

Then clear the PostgreSQL data directory on the backup server. No old data residue should remain there.

After that, copy the database base state from the primary server using pg_basebackup:

pg_basebackup -h SERVER_A_IP -D /var/lib/postgresql/data -U replicator -P -R

Replace SERVER_A_IP with the address of the primary server and adjust the target directory to your PostgreSQL installation.

5.6.7. Step 3: Start the Backup Server

Start PostgreSQL on the backup server. Synchronization begins automatically after startup.

5.6.8. Verify the Setup

On the primary server, the replication status can be checked, for example, with:

SELECT * FROM pg_stat_replication;

If the backup server appears there as an active connection, replication is running.

5.6.9. Behavior During Operation

5.6.10. Behavior in an Emergency

If the primary server fails, the backup server can be manually promoted to the new primary server:

pg_ctl promote

After that, the former backup server continues operating independently as the primary server.

There is no automatic failback to the original primary server. If the old primary server is to be used again later, it must be set up again as a replica or as a new primary system.

5.6.11. Notes


5.7. Initial Setup of WebPQ

The WebPQ must be initially set up with an administrator in the application layer and certain basic settings such as global password policies. The initial setup must always be performed when a new database connection to an existing WinPQ database is created in the administrative layer! Normally, the initial setup dialog appears automatically after the installation.

The basic settings are divided into eight areas:

  1. Welcome page

  2. Language and layout

  3. Time zone setting

  4. Password policy

  5. User identification and data

  6. Privacy policy

  7. Backup of the encryption key

  8. Summary

  9. Data adoption

Explanations of the sub-areas:


5.7.1. Step 2: Language and Layout

The language and layout are stored in the user account but can be adjusted again after login.

Initial setup step for selecting language and layout

5.7.2. Step 3: User Time Zone

The user's time zone must be set to display times correctly in different time zones. Each measuring point also receives its own individual time zone. The user can choose between different time zone views. Initial setup step for selecting the user time zone


5.7.3. Step 4: Password Policy and Company / Tenant Name 1

In the area of KRITIS, password policies per company are usually set by central IT. The setting here applies to all created passwords within the further administration. The setting can be changed individually afterward. See also: Tenant Settings

The following settings are possible:

Initial setup step for password policy and company or tenant name

1
Tenants are used to isolate resources (users, devices) through administrative rights and data storage. Each resource in WebPQ™ is held by its own tenant. A tenant typically represents a real company or a department/project within a company. Tenants are organized in a tree structure, so a tenant can have sub-tenants, and the sub-tenants can have their own sub-tenants. All administrative tasks can be performed by the administrators of a tenant and by the administrators of all higher-level tenants in the tree structure. Devices and users of sub-tenants are visible and accessible to the owning tenant in addition to the tenant's own devices. Tenant capability is a licensed module in the system.


5.7.4. Step 5: User Identification

Here, the main administrator of the system is defined. The used passwords must be kept secure. Recovery of the root account is only possible with data loss.

Initial setup step for creating the main administrator
The entered administrative password must be kept secure and must not be lost! Recovery without data loss is not possible!
Note

5.7.5. API and Swagger Access

The static Swagger and OpenAPI assets of WebPQ are not public download URLs. The customer API description at /swagger.html, /swagger.json, and /integration-swagger.json requires an authenticated WebPQ session or a valid bearer token.

For administrators and developers this means:

If an SMTP server is configured in the advanced settings, the password can be recovered using the password reset function with the entered email address.

Information on password reset can be found under: Forgot Password


5.7.6. Step 6: Privacy Policy

If you want to create an individual privacy agreement for your employees or customers, you can do so directly here. The software automatically logs the required information on the server in line with requirements such as those described in the BDEW/OE/VSE Whitepaper 3.0.

Information on audit logging can be found under: Audit Logging

Initial setup step for the privacy policy

5.7.7. Step 8: Data Adoption & Backup of the Master Key

The application encrypts sensitive data with a central encryption key using the AES-256-CBC method, known as the Master Encryption Key. This key is stored in the configuration file settings.json and is encrypted with the security functions of your operating system. Since the functionality of these security features may change due to operating system upgrades or migration to another computer, there is a certain risk of losing data encrypted with the Master Encryption Key. It is very important that you download or securely store this information NOW! There will be no further opportunity to do so.

After all data has been entered, it is transferred to the database, and the application is restarted.

Initial setup step for backing up the master key

5.8. Uninstallation / Removal of the Software

The WebPQ software is usually installed together with a locally running PostgreSQL database. Therefore, both the software and the database must be uninstalled in two separate steps if necessary.

5.8.1. Uninstallation of WebPQ Software

The uninstallation of WebPQ software is done through the Windows built-in uninstallation assistant. This can be accessed either through the Control Panel or by searching in the Windows Start menu.

5.8.2. Uninstallation of the Database

The database must be uninstalled through the Windows Services Management. The "WebPQDatabase" service must be stopped and removed. Then, the database files can be manually deleted.

Follow these steps:

  1. Open the Windows Services Management.

  2. Stop the "WebPQDatabase" service.

  3. Uninstall the "WebPQDatabase" service.

  4. Delete the database files in the database installation directory (default: C:\Program Files\WebPQDatabase).

Alternatively, the uninstallation can also be done via the command line. Open the command line with administrator rights and enter the following commands:

sc stop WebPQDatabase
sc delete WebPQDatabase

5.8.3. Deleting Temporary and Exported Files

The WebPQ software stores temporary files and exported files in the directory %programdata%/aeberle/webpq. These files can be manually deleted after uninstalling the software. However, ensure that no important data is lost. Similarly, files of exports and reports may be stored in directories set within the application. These should also be deleted.


5.9. Administrative Configuration / Backend of the Software

The administrative interface or backend may open with pre-configured connection settings during the initial installation. It can be accessed anytime on the host via the taskbar (next to the clock) by right-clicking the "WebPQ" icon and selecting "Administration."

During the initial setup of the software, usually only the hostname of the database server, the database name, and the username and password of the database need to be configured in the "Database" section. If the database is installed on the same host as the WebPQ software, the default values can usually be retained.

Once the settings have been saved and the processes have restarted, you will be asked if the application should be started with the embedded web browser. Clicking "Yes" opens the frontend in the app.

Open AppLogin

The administrative interface is divided into several areas, which can be accessed by clicking on the name in the top navigation: Service (#1), Database (#2), Network (#3), Paths (#4), Maps (#5), Data Sync (#6), Backup (#7), and Other (#8). The controls on the right of the navigation switch the color theme and the language of the interface.

Backend

5.9.1. Service

In the "Service" section, the user can monitor the status (#1), stop (#2), and restart (#3) the background service "WebPQService.exe," which runs under the "System" account. The same section also shows the running WebPQ processes (#4) and lets the user restart them when necessary (#5).

Service

Generally, the service that provides the web server for the clients should be both installed (Installed: Yes) and continuously running (Running: Yes).

The service starts automatically when the host starts and runs in the background. It is responsible for communication between the clients and the web server.


5.9.2. Database

The settings in the database section are necessary to establish a connection with the database server. The database connection settings can be found in WinPQ under "System Management >> Database" if an existing WinPQ database is to be used for WebPQ.

WinPQ database settings with the selected database connectionDatabase

The following table describes the settings from top to bottom, in the order shown above.

ParameterDescription
#1 TypeSpecifies the type of database used (PostgreSQL & MS-SQL) 2
#2 HostSpecifies the IP address / hostname of the server where the database is running
#3 Database NameName of the database where the measurement data is stored and where the WebPQ settings are also stored.
#4 PortSpecifies the TCP port under which the database server from #2 is reachable
#5 UsernameUsername with necessary write permissions on the database specified in #3
#6 PasswordSpecifies the password for the database connection user. The password is stored encrypted in the Windows Security Storage in the system user. For security reasons, it is not possible to read back the password in the interface! A password should only be entered when necessary changes are made!
#7 Database SchemaWebPQ stores data such as user settings, analyses, and many others in schemas. The default value here is always "public"
#8 SSLThe connection to the database server is generally encrypted (checkbox checked).
#9 Self Signed certificatesThe supplied certificates of the databases are by default "self signed." However, these can be replaced by company-specific certificates.
#10 Max parallel data uploadsSets the maximum number of parallel uploads to the database! By default, 5 is selected here. For large systems with high-performance databases, the number can be increased!
#11 Test connectionChecks if a connection to the database can be established with the entered data (e.g., if ports are open and all entered data is correct for a connection)
#12 SaveSaves the changed settings.

2
Licensed feature for MS-SQL - We recommend using the standard PostgreSQL solution in any case.

For MSSQL databases, the database schema dbo should be used.
Note

For a connection to a WinPQ system installed with its default settings, the following settings should be used.

5.9.2.1. Settings for installation up to WinPQ v6.2*

ParameterValue
#1 TypePostgreSQL
#2 Hostlocalhost
#3 Database NamePQID
#4 Port5432
#5 UsernamePQID
#6 PasswordPQID
#7 Database Schemapublic
We recommend changing "default passwords" in any case and using appropriate secure passwords according to your company policies! Instructions for changing passwords can be found in the WinPQ user manual.
Note

5.9.3. Network

The settings in this section refer to the web server installed on the host (server) in the form of the WebPQ application and the clients (evaluation PCs) that provide the interface.

The default settings are "security by default." For example, the web server on the installed PC is only accessible by clients via HTTPS on port 8443 (#2) by default. The service of an unencrypted connection is disabled by default (HTTP).

To use "HTTPS," i.e., the encrypted connection from the client (evaluation PC) to the web server, without a warning of an unknown certificate in the browser on the client (evaluation PC), it is recommended to store your own certificates protected with a password (#6) in the WebPQ application (#4 & #5).

To store the certificates, they must be in PEM format. More information can be found under PEM Certificates.

The certificates can be stored at the specified path and selected in the program interface by clicking (#4 & #5) on the path.

Network Settings
Using "unencrypted" connections and unknown certificates can lead to "data theft" and "data loss"! We always recommend using the "secure" default configuration (HTTPS)!
Note

5.9.4. Paths

In this section of the software, all paths where the software stores data are listed. This includes exports of reports in PDF format, data exports in various formats such as CSV and COMTRADE, as well as NEQUAL, log files like the audit log, and temporary files.

Paths

5.9.5. Maps

Use this section to choose the map source. Maps can be disabled, loaded from a local tile file, or retrieved from a tile server URL. When using a tile server, enter the provider attribution required by that provider.

A tile server URL must meet the following requirements:

WebPQ's own map server follows the URL schema https://maps.powerquality.cloud/maps/v1/<map-id>/tiles/{z}/{x}/{y}.webp, where <map-id> selects a specific map collection, for example de_germany.

Maps

5.9.6. Data Sync

This section configures device-data export, device-data import, and automatic file import. For each function, choose the target or source folder and enable it only when the corresponding file exchange is required.

Data Sync

5.9.7. Backup

Use this section for Preflight, Backup, Restore, and daily automated backups. See WebPQ Migration Tool for the complete backup and restore workflow.

For a backup, choose the target folder, confirm the automatically discovered entries, and select a protection method. Password protection is recommended. Use Preflight first to check paths, available disk space, and items that need manual attention; Start Backup creates the backup after Windows confirms the required Administrator rights.

For a restore, choose the backup folder or .zip file. Staging folder is the safe default: it restores a separate copy that can be inspected before it replaces a live installation. Select Original paths only when the target is ready to be overwritten; WebPQ stops the services before the restore and asks for confirmation. Enter the backup password when restoring a password-protected backup. Portable secrets from the backup are restored automatically and encrypted again for the target machine when its service starts. The optional secret fields are only for replacing values from the backup, for example for an external database with different credentials.

Backup

5.9.8. Other

This section shows the location of settings.json and configures audit-log writing. It also contains the WinReg compatibility setting. The settings file can support a controlled migration, but database passwords and certificates are not included.

Other

6. Operation & Usage

6.1. Accessing the Software Locally or via Client

The WebPQ software is opened on workstations via a web browser by accessing a specific link. This link may vary depending on the IT environment and installation. To ensure smooth use of the software, it must be ensured that the port defined in the installation is accessible from the workstation PC and a connection to the server with the installed WebPQ software can be established.

Examples:

Local Installation

If the server on which WebPQ is installed is also the workstation PC, the software can be opened in the browser using the following link.

https://localhost:8443/

Local Installation

Client-Server Architecture

If the WebPQ software is installed on a different PC (server) than the workstation PC (client), the address of the server (in this example, the server has the IP address 10.10.1.20) must be entered.

https://10.10.1.20:8443/

Client-Server Architecture

System Login:

Enter the username and password to log in directly to the system!

Login

6.1.1. Change Password

The user can set their login password directly via the Change Password function before logging in by entering their username and current password. The password policy set for the tenant must be observed!

Login

6.1.2. Forgot Password

If the system in the local installation has access to an SMTP server / mail server, it is possible to recover the password using the Forgot Password function and the email address assigned to the user.

In case of incorrect login attempts, the user will be blocked for five minutes after five incorrect attempts. The incorrect login attempts are also logged in the system.
Note

6.2. Software Layout and Functions

6.2.1. Analysis - Types and Options

The software is divided into the following areas for PQ and other analyses:


6.2.2. Reporting - Types and Options

The "Reporting" area includes all settings required for creating normative reports (PQ standard templates). It also offers the possibility to define automated tasks (automation tasks) to execute reports and data exports on a scheduled basis.

Reporting Overview

6.2.3. Import / Export

The Import/Export area includes all interfaces for data and report exchange between the WebPQ platform and external systems. Here, measurement data can be imported, reports and raw data can be exported, and synchronization processes can be monitored. Additionally, functions for manual download of PDF reports as well as CSV and measurement data import are available.

Import / Export

6.2.4. Settings / Administration

The Settings area includes all administrative functions of the software. This includes the configuration of measuring points, user and rights management, and tenant management. Additionally, other central settings are available here, such as device tagging, license management, and – if licensed – fleet management.

Settings Overview

6.3. User Interface of the WebPQ Software

The WebPQ application is divided into three main areas:

  1. Navigation Bar: The navigation bar #1 is located on the left side. For smaller screen resolutions, it is moved to the top area. In this case, the navigation can be opened by clicking on the three lines.

Compact navigation bar with hamburger menu
  1. Header – The header contains important controls and information:


  1. Workspace: The central area #5 of the application, where the actual content and functions are displayed and edited. This is where data entry, analysis, and visualization take place.

WebPQ user interface with navigation bar, header, and workspace

To use the workspace as efficiently as possible, you can reduce the navigation bar to compact buttons. To do this, the Always Expand option #1 must be deactivated. This way, the navigation is only displayed when needed, providing more space for the actual workspace.

Collapsed navigation bar with compact icons

6.3.1. System Messages / System Status

To organize the system with connections to many measuring points and to operate the system in a stable fashion, the software lists all messages centrally and clearly via #1.

If the exclamation mark turns red Red exclamation mark status icon, new system messages – such as connection interruptions or messages about the battery status of the measuring devices – have occurred. If the exclamation mark is green Green exclamation mark status icon, all messages have been acknowledged (#3) or no new critical messages have occurred.

System messages overview with filter options and message table

All messages can be acknowledged as a whole (#3) or individually by clicking on the message as shown in the screenshot below (#1) for each device / globally and per user or globally. To do this, select the option under device or user in the dropdown list and confirm this via #3.

Dialog for acknowledging individual system messages per device or user

It is also possible to "silence" individual messages. This may be necessary, for example, when shutting down a connection for maintenance purposes. To do this, select function #2 "Silence Message". This function can also be set per device or globally for the message type per user or for all users. The "silenced messages" button Button for silenced messages allows you to view and reactivate the silenced messages. To do this, simply click on Icon for reactivating a silenced message in the respective row of the message to be reactivated.


6.3.2. Account Settings

Each user can open the account settings from the displayed account name in the WebPQ header.

Open account settings

The account settings are split into the tabs My Account, Theme Settings, Application Settings, CSV Settings, and Permissions. Tabs with unsaved changes are marked with an asterisk. When you try to leave such a tab, WebPQ asks whether the changes should be saved, discarded, or whether you want to stay on the current page. If several independent theme settings are changed at the same time, the prompt only offers to discard the changes or stay on the current page.

6.3.2.1. My Account

Account settings account tab

The My Account tab contains the editable personal data for the signed-in user:

Your timezone applies to user-specific views and exports. With Timezone used for measurements, choose the personal default for displaying measurement timestamps in all analyses: Device Timezone (falling back to the user timezone if the device timezone is invalid or missing), User Timezone, or UTC. WebPQ stores measurement data in UTC; your choice changes neither stored timestamps nor the device timezone. A view-specific timezone setting takes precedence. Device Timezone is generally recommended because a permanently installed measuring device is associated with a location and its time zone.

The PDF page orientation is used for manually created reports. Choose Tenant settings to inherit your tenant's orientation; the effective value is shown next to that option. Users permitted to change tenant settings can open the tenant report settings from the link beside the orientation heading. Fault records (DFR) exported as PDF are always printed in landscape, independent of this setting; fault-record analyses in a printed dashboard follow it. Click Save to apply changes, or Reset to discard unsaved edits. The displayed account name in the header updates immediately after the save.

6.3.2.2. Theme Settings

Account settings theme tab

The Theme Settings tab controls the personal appearance of WebPQ:

Font size and color scheme changes are applied immediately after saving. Changing the language stores the new language selection for the user and updates the WebPQ user interface.

6.3.2.3. Application Settings

In Application Settings, choose how device names are displayed for your account. Configure Device Display Names beside a device label opens a standalone page with the same settings. The label itself is edited on the device; the display options below change neither the label nor the database ID. Changes to the display options apply to the signed-in user.

6.3.2.3.1. Device display names

The preview on the device tree immediately shows the display name composed from the device label, tags, and database ID. Reset to default restores the default display options.

Within an analysis, you can override these options under Analysis Layout via Device name settings; unchanged values are inherited from your account settings (see Analysis Layout).

Device display names in Application Settings

6.3.2.4. CSV Settings

Account settings CSV settings tab

The CSV Settings tab defines the default format used for CSV downloads:

These settings are used when WebPQ creates CSV files for the current user. Click Save to apply changes.

6.3.2.5. Permissions

Account settings permissions tab

The Permissions tab shows the permissions assigned to the current user. The table is read-only and can be sorted. Permissions are managed in the administration area, not in the account settings page.


6.4. Visualization Pages

6.4.1. Grid > Overview

6.4.1.1. Grid Overview – Heatmap

The homepage of the Grid > Overview software provides the user with a quick overview "Heatmap" of all devices connected to the WebPQ software. This overview spans a selected time period, #1, typically a calendar week. The landing page is automatically updated every 60s to always display the latest disturbances. Using the #2 function, the interface can be sorted into custom hierarchy levels, allowing many measurement points to be displayed hierarchically according to the application. More information can be found under Hierarchy Settings

The devices are sorted by default according to the number of disturbances in the #3 area. Disturbances are color-coded:

Clicking on an OSC or TRMS record opens the Analysis Cockpit. Subsequently, the button color with the number of records changes from red to green.

Grid Overview

In the PQ – Events#4 area, the number of power quality events is listed based on the power quality standard stored and set in the measuring device – e.g., EN50160 or IEC61000-2-4.

Clicking on the -/+ allows the individual areas to be expanded or collapsed. In the collapsed state, the maximum values of the subordinate measurements are always used for the display.

In the Long-term Data#5 area, the statistical data is calculated according to the standard stored in the measuring device. These include:

When the mouse pointer hovers over an abbreviation, an explanation is displayed via a tooltip.

Tooltip

Clicking on the designation, e.g., PLT, sorts the display either from the worst to the best measurement point or vice versa. This function facilitates the identification of the most noticeable measurement points for the respective measurement value.

Clicking on the respective measurement values – e.g., THD – opens the Analysis Cockpit. This allows the abstract representation of the measurement values to be converted into a temporal representation for detailed analyses.

THD

In the Harmonics#6 area, all harmonics from H2 (100 Hz) to the 50th harmonic (2500 Hz) as well as the Supraharmonics#7 are listed in relation to the respective limit value. The color scale in the statistical measurements shows the proximity to the limit value:

To quickly find a desired measurement point, the name of a measuring device can be entered in the Search Bar#8 area. The display is then interactively filtered.

Clicking on a device name#9 switches the application from Grid >> Overview to the Analysis >> Device page.

6.4.1.1.1. Indicators and saved column groups

Reserve values use blank colored squares by default. To use circular gauges in the global overview, enable Show gauges under My account > Application settings > Heatmap. Each cockpit heatmap has a separate Show gauges switch in its parameter dialog, to the left of Weeks as rows. The gauge choice also applies to single-week intervals. Counts and valid-measurement percentages remain numeric squares in either mode. Missing data stays empty; hover over a reserve indicator to see its value and threshold. Clickable detail squares have a rounded outline; their tooltip names the analysis they display. Click a collapsed group's summary square or gauge to expand the group. Summary indicators have no outline. The + and − controls in the group header expand and collapse the same columns.

Opened and closed column groups are restored after a page reload. The overview saves these choices automatically in your profile. Each cockpit widget keeps its own choices: use Save tab before reloading. Changing the selected metric or editing a widget's parameters does not discard its group choices. Groups you have not toggled still use the defaults for the available width.

6.4.1.1.2. Comparing several calendar weeks

The heatmap on the Grid > Overview page always shows exactly one calendar week. When the same table is added to a cockpit as the Grid Overview Table analysis, it follows the configured analysis interval instead: every calendar week of that interval gets its own block of columns headed CW <week>/<year>, so the weekly values can be compared side by side.

This enables a new multi-week heatmap view inside analyses. It offers four display modes that are set with the two analysis parameters Weeks as rows and Metric in the parameter dialog, next to the other parameters of the analysis:


6.4.1.2. Grid Overview – Tile View

In the second area Grid Overview – Tile View, all devices with their essential live values are displayed within the configured hierarchy levels.

Grid Tile View

With Enable Edit Mode #1 the tile arrangement can be changed via drag & drop and devices or groups can be assigned to other hierarchy levels. After Save the adjustments are stored persistently and loaded on next access. Changes apply system-wide for all users and can be centrally managed by the administrator.

Via Change Default Displayed Measurements you can define which live data appear in the tiles. All real-time values provided by the measuring device are available. Settings can be made

Usage:

Group Edit View

The refresh interval of the live data is configurable. The hierarchy order can be adjusted using drag & drop in the upper right corner.

A tile contains the following elements in live operation:

Tile Example

#1 Connection status: Red = no connection, Green = connection active #2 Link to the Power Quality report (e.g., EN50160, IEC61000-2-4) #3 Link to device parameterization #4 Display of the configured live data

6.4.1.3. Grid Overview - Map View

Map View allows users to see devices on a map and combine the geographical view with threshold utilization, fault records, and PQ events for the selected time range. It is intended for quickly locating affected areas and then jumping to the relevant analysis or device settings.

6.4.1.4. Setup

Prerequisites

Configure the path in the WebPQ backend

  1. Open the WebPQ backend.

  2. Scroll to Paths.

  3. Set the Maps Storage Folder field to the desired folder.

  4. Save the change (Update) so the setting is applied.

Place the maps package in the maps folder

Verification

Troubleshooting

6.4.1.5. Functionality

6.4.1.5.1. Device Settings

To display a device in Map View, the device geocoordinates must be configured first. Open Device Settings and select a device. The device position can be configured in the General tab. Enter latitude and longitude, or set the coordinates by clicking on the map.

Device Settings Map View
6.4.1.5.2. Map View

Map View is divided into three areas:

View settings

Contains the following UI elements:

Map

The current map center and zoom are stored in the page URL. Copying the URL, switching between overview tabs, or using browser Back restores the same map viewport.

Initially, Map View shows all devices that have a configured geolocation. Multiple nearby devices are shown as a cluster with the number of devices. Clicking a cluster zooms in until individual devices are visible.

Threshold utilization contributes to the marker color. Its threshold status uses the highest currently calculated utilization of the device and all descendant devices, including descendants without their own marker. Synchronization, fault-recording, and PQ-event status also contribute. A marker is red if any status is critical or new, yellow if its worst active status is a warning, and green otherwise.

Each device is shown with a pin and the device name. Clicking a pin opens a tooltip with information about the device. Moving the pointer over a pin does not open the tooltip.

The General information section is initially collapsed. Expand it to see the device name, links, hierarchy tags, address, and connection information.

The threshold-utilization and fault-recording section is initially expanded and shows:

Selecting a device from one of the bottom-panel tables centers the map on that device and opens the tooltip. Devices without configured geodata remain visible in the tables, but they cannot be focused on the map until a location is configured.

Information Panels

At the bottom of Map View there is a panel with four columns. Above each column there is a heading with relevant links to other areas of the application.

Clicking any device name centers the map on that device and opens the tooltip. Each information panel column can be expanded or collapsed using the small arrow button in the column header. Collapsed columns appear as narrow tabs on the left side. Column width can be adjusted by dragging the separators. The overall panel height can also be resized. Column widths, collapsed states, panel height, and the Show only visible devices setting are saved and restored when Map View is opened again.

Devices:

Shows the currently relevant devices together with the configured address. Depending on the Show only visible devices toggle, this is either the current map viewport or the complete device set. The table supports sorting and filtering by device name and hierarchy tags.

Fault Records:

Shows recorded fault records for the selected time range and the currently relevant devices. The heading contains a direct link to the Fault Records page.

The table shows the time, device, type, and trigger-related information. Clicking a fault-recording type opens the detail view directly in the panel.

Thresholds and utilization:

The header contains a shortcut to the corresponding cockpit analysis for the selected time range.

Utilization of the user-defined thresholds of the devices.

Users see the maximum utilization of the thresholds defined for each device. These device, utilization, and threshold columns are also used in the marker tooltip. Clicking a utilization percentage opens the Analysis Cockpit with the corresponding threshold data. Clicking a threshold value opens the related threshold settings, if a reporting setting is available.

The application is able to assign a threshold to each measured value and display the utilization here as a maximum value. More in the chapter "customer-specific thresholds". @Fabian insert link to new Threshold chapter here.

PQ Events:

Lists PQ events for the selected time range and the currently relevant devices. The heading contains links to the PQ Events over Time analysis and the PQ Events page.

The table shows the event time, device, linked OSC/TRMS recordings, event type, and the measured value. Sorting and filtering can be used to narrow down the list to specific event types or devices.


6.4.2. Grid > Fault Records

In the Grid > Fault Records area, all disturbances within a freely selectable time period #1 are displayed in a list.

The display offers the following functions:

Fault Records Overview

In the #4 area, the user can set individual filters. In the shown example, a filter on duration > 50 ms is set, displaying only disturbances in this range. The table can also be sorted by type, time, device, trigger, duration, and other available columns.

The device column supports both free-text search and selection through the device tree. If hierarchy display is enabled, the configured device tags are shown directly in the list so that disturbances can be grouped more easily by location or structure.

Clicking on OSC or TRMS#1 opens the Quick View window from the right.

For advanced analysis options, setting markers, or describing the disturbance, the Analysis Cockpit can be opened via #2.

Clicking a device entry opens the corresponding device page at the event time. This helps when the fault record needs to be checked together with device details or configuration.

Quick View Window

To view two or more fault records in parallel, multiple disturbances can be selected via the selection function. The selected records can then be loaded together into the analysis view for direct comparison.


6.4.3. Grid > PQ Events

Power Quality Events

In the Grid > PQ Events area, all Power Quality Events (not disturbance records!) within a freely selectable time period #1 are displayed in a table.

The display offers several search and filter functions#2:

Above the table, the same date-range jump buttons as in the fault-record view are available. The table also provides a hierarchy toggle so that configured device tags can be shown or hidden in the device column.

The device filter only offers devices that actually have PQ events in the selected time range. This makes it easier to narrow large installations down to the relevant sources quickly.

Additionally, existing disturbance records can be opened directly in a Quick View via the OSC and TRMS#8 links.

The Description column is derived from the PQID metadata of the event type. This means the table shows the translated event description that belongs to the stored PQ event.

The current result set can be exported directly via the Export button above the table.

Clicking on OSC#1 opens the Quick View window from the right.

For advanced analysis options, setting markers, or describing the disturbance, the Analysis Cockpit can be opened via #2.

Quick View Window

6.4.4. Operation in the Analysis

6.4.4.1. Zooming in the Analysis – Zoom In / Zoom Out

To zoom, use the left mouse button or, on a touch display, the standard two-finger zoom gesture.

You can save the zoomed area using the "Keep Zoom" function #1. To reset the zoom to its original value, use "Reset Zoom".

Zoom Function

6.4.4.2. Submenu in the Analysis #2

Note:
Exports, including PDFs, are stored on the server. The storage location is defined in the server settings in the WebPQ backend and can only be changed by the administrator. Installation Paths

Submenu

6.4.4.3. Show & Hide Measurements on the Y-Axis

By clicking on a measurement#1, individual measurements can be selected or deselected. Deselected measurements are automatically moved to the bottom. Measurements are always displayed in order of their height on the Y-axis.

6.4.4.4. Analysis Cockpit

The Analysis Cockpit can be accessed and opened at any time via the button Analysis Cockpit Button.

More information about the Analysis Cockpit can be found under Link


6.5. Analysis

The Analysis Cockpit is the central workspace and analysis area, offering various types of analysis, including:

6.5.1. Analysis Cockpit

You can open the cockpit in several ways:

Add Analysis

6.5.1.1. Structure of the Analysis Cockpit

The Analysis Cockpit is divided into two sections:

Analyse Overview

Key functions in the Analysis Cockpit:

Note:
The Analysis Cockpit settings are saved in the browser cache. This means data is retained even if the analysis is not saved in the dashboard.


6.5.2. Basic analysis settings

6.5.2.1. Analysis settings

Under #1, select the desired analysis type. By default, the level-time diagram is pre-selected. Alternatively, other types such as latest data tables, histograms or, for power quality event analysis, the ITIC graph can be chosen as the evaluation type.

Analysis Settings

With the time setting#2, you can open a dialog to configure the analysis period. If an absolute period has been defined in the

menu, it can be set either by directly entering the start and end time under #3 or via the input fields.

In the device section #3, select the devices to be evaluated. This can be done by entering the device ID or using the selection list by clicking #3. The list shows all devices available in the database.

Using the measurement variable tree#5, select the measurement values recorded by the chosen devices during the selected period and transferred to the database. The selection can be reset with #4.

Depending on the analysis type, specific parameters must be considered for correct evaluation. These are explained in the following sections.


6.5.2.2. Analysis types

6.5.2.2.1. Level-time diagram

The level-time diagram displays selected measurement values as a line chart over a defined period. It is ideal for temporal analysis of measurement values and their changes.

Level-time diagram

A special feature is the integration of flagging according to IEC61000-4-30 Class A. If enabled, flagging information is shown directly in the measurement variable tree #1 within the measurement series.

Measurement variable selection is dynamic: It is based on the intersection of available data, restricted by parameters such as period and selected devices.

See also: Time settings for experts

6.5.2.2.1.1. Displaying Thresholds

In the "Analysis Evaluation" tab, you can display the thresholds stored in the measuring device for the selected measurement variables. From version v2.1, alternative threshold sets can also be selected and applied to the measurement data.

Display Thresholds

To show thresholds, select either the standard thresholds #1 or the extended threshold sets #2. Thresholds are then automatically displayed in the chart.

Extended threshold sets can be customised and managed in Reports > PQ Standard Templates. You can create, edit, or delete threshold sets there.

6.5.2.2.1.2. Display of flagging status

Flagging is visualised as a normal measurement value and displayed in the measurement series.

Flagging display
6.5.2.2.1.3. Setting markers for detailed analysis

In the level-time diagram, up to two markers can be set for detailed examination:

  1. Set marker:

  2. Remove marker:

Marker values are automatically displayed in analysis evaluation and can be used for further analyses.


6.5.2.2.2. PQ events over time

The PQ events over time diagram visualises recorded and selected power quality (PQ) events within the defined time range.

PQ events over time
6.5.2.2.2.1. Interactive analysis

6.5.2.2.3. Histogram

The histogram shows the statistical distribution of a selected measurement variable within a defined period.

Histogram
6.5.2.2.3.1. Functions and analysis

6.5.2.2.4. Scatter plot

The scatter plot visualises the relationship between two selected axis values as a cloud of points. Each point represents one individual measurement record. This analysis type is especially useful for spotting correlations, clusters, outliers, and distributions quickly.

Unlike the level-time diagram, the scatter plot focuses on the relationship between two characteristics instead of their temporal progression. This makes it easier to compare measurement variables directly or structure data by device, tag category, or plot group.

Scatter plot
6.5.2.2.4.1. Typical use cases
6.5.2.2.4.2. Important settings

6.5.2.2.5. Latest Data Table

The Latest Data Table shows the most recent available measurement values for the selected devices and measurement variables in a compact table. It is intended for quickly comparing the current or last known state of several devices without switching between individual device views.

6.5.2.2.5.1. Typical use cases
6.5.2.2.5.2. Important settings
6.5.2.2.5.3. Table behaviour
6.5.2.2.5.4. Threshold display and ageing
6.5.2.2.5.5. Practical interpretation

The Latest Data Table is especially useful when you need an operational overview instead of a time history. Use it to identify missing updates, compare the latest state across several devices, and jump from a condensed table to more detailed analyses when a value needs further investigation.


6.5.2.2.6. FFT Spectrum

The FFT Spectrum analysis is used to inspect the frequency spectrum of oscilloscopic measurement data. It is useful when periodic signal components, resonances, or dominant frequency bands need to be identified directly from time-domain recordings.

6.5.2.2.6.1. Prerequisites
6.5.2.2.6.2. Historical FFT

Historical FFT is based on stored oscilloscopic data in the selected time range. It is suitable for analysing already recorded events or archived oscilloscopic measurements.

This analysis helps identify characteristic frequencies after a disturbance and compare the spectral content of different oscilloscopic channels.

6.5.2.2.6.3. Live FFT

In addition to historical FFT, WebPQ also provides Live FFT as a dedicated live analysis type.

Live FFT is useful for observing changing spectral content while a signal is still being streamed.

6.5.2.2.6.4. FFT options

Depending on the selected oscilloscopic data, additional FFT options are available in the parameter area:

6.5.2.2.6.5. Application areas

6.5.2.2.7. Custom Threshold Utilization Report

The Custom Threshold Utilization Report compares the maximum measured values of the selected interval with the configured maximum values of custom threshold settings. It is intended for quickly identifying devices that already use most of their individual threshold reserve.

6.5.2.2.7.1. Prerequisites
6.5.2.2.7.2. Display and content

The analysis is shown as a table. Depending on the selected view, it includes in particular:

The default sorting is by the highest utilization. With Advanced view, additional columns such as the unit can be shown.

6.5.2.2.7.3. Interactive functions
6.5.2.2.7.4. Color logic

Utilization is shown as a colored progress bar:

This makes it easy to identify critical devices at a glance.

6.5.2.2.7.5. Reasons for unavailable values

If a value cannot be calculated, the table shows a warning indicator with the corresponding explanation. Typical reasons are:

6.5.2.2.7.6. Application areas

6.5.2.2.8. Voltage and current harmonics as bar charts

Voltage and current harmonics are displayed as bar charts to provide a quick overview of the entire frequency spectrum to be monitored.

Harmonic analysis
6.5.2.2.8.1. Display and interpretation

6.5.2.2.8.2. Visualisation methods

Voltage:

Current:

6.5.2.2.8.3. Dynamic settings

Depending on the selected visualisation method, additional settings are shown or hidden to optimise analysis.

6.5.2.2.8.4. Application areas

This analysis is useful for:

6.5.2.2.8.5. Limits in analysis

Measuring devices from A. Eberle GmbH provide current limit sets directly to the database. These limit sets form the basis for analyses and reports.

6.5.2.2.8.6. Dynamic adjustment of limits

Since harmonic limits are percentage values based on recorded aggregation levels, alternative limit sets can be applied to existing data in the UI.

Select limit set:

Display limits in visualisation:

Switch between representations:

6.5.2.2.8.7. Application areas for voltage and current harmonic bar chart analysis

6.5.2.2.9. Current Harmonics Analysis

The Current Harmonics Analysis evaluates measured current harmonics against a selected current grid-code reporting template (Limit_iharm). It is separate from the standard voltage and current harmonic bar chart analysis because it uses current-specific grid-code limit calculations and the measuring-site parameters of the selected device.

To run the analysis, select exactly one device, one data class, one analysis interval, and one Limit_iharm reporting template. Then choose whether to evaluate harmonics, interharmonics, or supraharmonics. The result can be shown as one bar chart per current phase (i1, i2, i3) or as a table.

Values can be displayed either as absolute current values in A or relative to the calculated current limit in %. In the relative view, 100% represents the selected template limit; values above 100% indicate that the measured maximum exceeds the calculated limit. If the limit cannot be calculated, check the selected reporting template and the device measuring-site parameters.

The calculation uses the measuring-site parameters configured under Settings > Devices > Measuring site parameters. Users without metadata editing rights can still view that tab for supported devices, but only users with metadata edit permission can change the values.


6.5.2.2.10. Supraharmonic analysis

The "Supraharmonics" analysis shows – depending on device data – the supraharmonics in the context of the selected standard template and time range.

Supraharmonic analysis
6.5.2.2.10.1. Determination of supraharmonics

Determination follows IEC 61000-4-7 in 200-Hz frequency bands.
In the software, centre frequencies are always shown.

Example of frequency band division:

Supraharmonics are visualised as bar charts.
The display can be adjusted according to standard requirements and analysis goals.

6.5.2.2.10.2. Functionality of analysis

Supraharmonic analysis has the same functions as harmonic analysis:

6.5.2.2.10.3. Application areas for supraharmonic analysis

6.5.2.2.11. Interharmonic analysis

Interharmonic analysis investigates voltage and current components not in an integer ratio to the fundamental frequency.

6.5.2.2.11.1. Display of interharmonics

Interharmonics are visualised as bar charts.
Various display types can be selected:

This analysis is relevant for evaluating harmonic distortions caused by frequency converters, electronic loads, or nonlinear consumers.

6.5.2.2.11.2. Functionality of analysis

Functionality matches harmonic analysis and offers:

6.5.2.2.11.3. Application areas for interharmonic analysis
Interharmonic analysis

6.5.2.2.12. Normative report - Voltage quality (e.g., EN50160)

The normative report summarises all values required for evaluation according to the set standard templates in a clear analysis.

6.5.2.2.12.1. Display and functions

Results are available in two formats:

Normative report - Voltage quality

If no dedicated standard template is assigned to the selected device, the template provided by the device is used automatically.
The title is generated from the stored standard template of the device.

6.5.2.2.12.2. Adjustment of measurement variables based on the standard template

Depending on the template, specific measurement variables are included or excluded.

Examples:

In the example shown, a combined template of EN50160 and IEC61000-2-2 is active, so supraharmonics are also displayed.

6.5.2.2.12.3. Evaluated parameters in the normative report

Various parameters are evaluated according to the set standard template. Each parameter is displayed with its limits.

6.5.2.2.12.4. Frequency (#3)

Network frequency must be between 49.5 Hz and 50.5 Hz according to EN and IEC.


Frequency evaluation

6.5.2.2.12.5. Voltage (#4)

Network voltage is evaluated relative to the nominal value.

6.5.2.2.12.6. Unbalance (#5)
6.5.2.2.12.7. Long-term flicker (PLT) (#6)
6.5.2.2.12.8. THD (Total Harmonic Distortion) (#7)
6.5.2.2.12.9. Individual harmonics (maximum values per phase) (#8)
6.5.2.2.12.10. Supraharmonics (maximum value per phase) (#9)

6.5.2.2.13. Comment box
Comment box

The comment box is used to add extra information or explanations to analyses created in the dashboard.

6.5.2.2.13.1. Functionality
6.5.2.2.13.2. Markdown support

For simple formatting, Markdown syntax is used.
Examples:

For security, executable HTML and unsafe links are removed when the comment is displayed.

A full overview of Markdown syntax is available in the Markdown Cheatsheet.

6.5.2.2.13.3. Application areas

6.5.2.2.14. ITIC (CBEMA) curve
ITIC (CBEMA) curve

The ITIC (CBEMA) curve describes an AC input voltage typically tolerated by most information technology equipment (ITE).

6.5.2.2.14.1. Functionality
6.5.2.2.14.2. Analysis settings
6.5.2.2.14.3. Interactive evaluation

6.5.2.2.15. FRT Curve

6.5.2.2.15.1. General Information about the FRT Curve and Application Areas

The FRT curve (Fault Ride Through) illustrates how generation units such as photovoltaic or wind power plants can continue feeding into the grid during voltage dips. WebPQ enables graphical visualisation and analysis of FRT curve compliance according to country-specific grid codes. In "Report → Standard Templates → FRT Curve", the appropriate FRT curve for different countries and grid levels can be selected or defined. Measured voltage events are plotted against the FRT curve, making it easy to see whether the plant meets requirements. The FRT curve is an important tool for grid operators and plant owners to ensure grid stability and compliance with legal and regulatory requirements.

The FRT curve is typically displayed as a percentage of nominal voltage over time. It shows permissible voltage dips and the required duration for which a plant must continue feeding during these dips. The curve starts at 100% of nominal voltage and drops during an event. Depending on the grid code, requirements for depth and duration of the dip vary.

FRT Analysis

Plotted events are interactive: Clicking an event opens the corresponding disturbance record for detailed analysis.

Depending on the available data, a disturbance record is plotted either with its detected voltage events or with a single depth/duration marker. Detected voltage dips (downward triangle) and voltage swells (upward triangle) are plotted at the duration and residual voltage the automation trigger evaluates; the tooltip lists the affected channels, the exact duration and the residual voltage.

6.5.2.2.15.2. Adding a Custom FRT Curve

Creating, editing, and migrating custom profiles, including the requirements for fault-record filtering, is described under FRT Curves in Reporting Templates.

6.5.2.2.15.3. Applying the FRT Curve in Analysis

FRT - Analysis Cockpit


6.5.2.2.16. Event matrix

The PQ event matrix is based on EN50160 and correctly assigns power quality events according to the standard by depth and duration.

PQ event matrix
6.5.2.2.16.1. Functionality
6.5.2.2.16.2. Standard-dependent display

Depending on the regional standard, different tabular display forms exist:

The correct assignment and display can be selected via the standard template. Only the correct template needs to be selected.

6.5.2.2.16.3. Flexibility of analysis

Example: Netcode

Netcode

Example: NRS048

NRS048
6.5.2.2.17. Live values

All directly connected device classes of types PQI-DA smart, PQI-DE or PQI-LV are live retrievable via direct data connection using TCP/IP streaming.

Measurement value display can be done in various analysis forms with a good data connection.

Important notes

⚠ High data consumption: Displaying live values generates very high data transfer!

⚠ Prioritisation of live data:


6.5.2.2.17.1. Live oscilloscope image

The oscilloscope image is fully downloaded from the device and displayed in regular quasi-stationary states.

Live oscilloscope image

6.5.2.2.17.2. Live measurement values

This analysis type is ideal for parallel comparison of multiple measuring points.

Live measurement values

6.5.2.2.17.3. Live time series

This analysis type is well suited to quickly visualise reactions at measuring points to switching actions or direct influences.

Live time series

6.5.2.2.17.4. Live harmonics

This analysis type shows all harmonics relative to the fundamental wave live.

6.5.2.2.17.5. Live interharmonics and harmonics

This analysis type works identically to live harmonics analysis:

6.5.2.2.17.6. Live vector diagram

Live vector diagram

The vector diagram (phasor diagram) displays voltage and current phase angles in a three-phase system.

It is especially useful for checking device connections, as wiring errors or unsuitable consumer characteristics can be detected.

What does the vector diagram show?

How to interpret the vector diagram?

1. Phase shift between voltage and current
The phase angle between voltage and current indicates the load type:

2. Detect wiring or connection errors

Application areas of the live vector diagram


6.5.2.2.18. Analysis evaluation
Analysis evaluation

Analysis evaluation offers various options for detailed examination of analysed measurement values.

6.5.2.2.18.1. Display marker values (#1)
6.5.2.2.18.2. Display extreme values (#2)
6.5.2.2.18.3. Analyse limit values (#3)
6.5.2.2.18.4. Application areas

6.5.2.2.19. Analysis layout

In "Analysis Layout", grouping methods #1, scaling #2, and colours #3 of measurement values can be defined.

Using "Group by", measurement values can be displayed individually:

Use "Settings for device names"#4 to adjust the device-name presentation for the current analysis:

Under Series Label#7, choose how the measured quantity is named in the time-series legend. Options are Source label with mapping DB field, Source label with DB field (default), Mapping DB label, and DB field name. The source label comes from the measurement data; the mapped label is the readable name from the measurement mapping, while the DB field name is the technical field identifier. If a source label is unavailable, WebPQ uses the mapped label. This setting changes only the displayed series label, not the measurement data or device display name.

Values that are not customised inherit your Application Settings for device display names. Changes in the Analysis Cockpit apply to the current analysis and are stored with it in the analysis dashboard. The technical database identifier remains the device identity independently of the visible presentation.

Analysis Layout
6.5.2.2.20. Widget settings

Under "Widget settings", you can adjust the title and size of the widget.
These settings are relevant when the analysis is transferred to the dashboard and saved permanently.



6.5.3. Analyze Device

This view offers detailed and pre-configured analysis functions for individual measuring devices to specifically access their data.

The view is divided into three areas:

PQ Report

As a user, you have the option to switch the measuring device via #4 and switch between the data weekly.

The Power Quality Report consists of four types of analysis:

  1. Summary of the necessary measured variables according to the set norm template in a clear bar chart based on the limit values.

  2. Explanation of the EN50160-relevant measured variables.

  3. List of disturbances recorded by the measuring device.

  4. List of PQ events in the EN50160 matrix.

By clicking on the bars, the drill-in procedure opens to display the measurement data in detail.

In the "Analyse Device"#2 tab, there are pre-configured level-time diagrams, histograms, and the ITIC curve.

In the Live Data#3 area, the user has the option to visualize the live data of the device if the selected measuring device is directly connected.


6.5.4. Analysis > Dashboard

The Analysis Dashboard, which can be found in the navigation bar on the left side under "Analysis > Dashboard" #1, is used for the permanent storage of analyses in widgets that were created via the Analysis Cockpit. Using the Add analysis function #2, it is possible to open the Analysis Cockpit, define an individual analysis, and transfer it to the Analysis Dashboard.

Dashboard

With the "Tab settings" function #3, the time period for all analyses stored in the tab can be changed. For example, in one widget, you can select performance, and in another widget, you can select maximum currents, voltages, and THD (Total Harmonic Distortion). To compare the dependencies of the variables with each other weekly, the time period for all widgets can be adjusted via the Tab Settings. Click on "Tab Settings" and change the time range for the tab and all analyses contained within it.

The "Save Tab" function #4 saves settings such as window sizes, zoom levels, markers, etc. The button is enabled as soon as the current tab contains unsaved changes and remains disabled while the tab is unchanged. If changes have been made, the user will be prompted to save or discard the changes when leaving the Analysis Dashboard. Unsaved tabs are marked with a "*", making them easy to find again to complete the saving process.

With the #5 function, tabs can be duplicated and saved under a new name. The #6 function deletes the tab directly. However, if a tab is closed via the X next to the tab name, it is not deleted but can be displayed again at any time via the tab menu #7 in the tab bar.

The Tab Menu opens the tab menu. In the "Load Saved Tabs" area, all tabs can be transferred back to the interface from the background storage. To create a new tab, click on "+ Create New". To save the tab copied using function #5 into a new one, use the "Add Tab" function and paste the content into the empty field using CTRL+V.

6.5.4.1. Copy and Paste Dashboard Content

Copied dashboard content can be reused in two ways:

The import preview shows the analysis type, devices, and interval for each analysis. If the copied source tab used tab-wide time settings, WebPQ keeps that source interval for the imported analyses so the content matches the original tab. If the pasted content is not valid JSON or cannot be read as an analysis or tab, the dialog shows the problem directly before anything is imported.

6.5.4.2. Group Dashboards

In addition to personal dashboard tabs, WebPQ also supports shared Group Dashboards. The page is available in the left navigation under Analysis > Group Dashboards and shows the dashboard tabs of all groups the current user belongs to.

Create a Group Dashboard

Group dashboards are created by transferring an already saved personal dashboard tab:

  1. Open Analysis > Dashboard.

  2. Save the tab first. Unsaved tabs cannot be transferred.

  3. Click Transfer to Group Dashboards in the tab toolbar.

  4. Select the target group.

  5. Confirm the transfer.

After a successful transfer, the tab is removed from the personal dashboard and becomes a shared group dashboard tab.

Open and find Group Dashboard tabs

Edit shared tabs

Once a shared tab is opened, it behaves like a normal analysis dashboard tab:

This makes group dashboards suitable for shared team views that should stay identical for all members of the same group.

Conflicts while saving

If another user saves the same group dashboard tab before your changes are stored, WebPQ detects the version conflict and offers three options:

The dialog also shows which user last edited the tab and when the latest change was saved.

Notes


6.6. Time Settings in Analysis

The time setting#1 in the analysis allows the user to open a dialog window for configuring the analysis period and to define extensive time options relevant for the analysis of equidistant measurement values.

Time Settings

In general, four different modes are available:


6.7. Reporting - PQ Standard Templates

In the menu under "Templates & Tasks >> Reporting Templates", templates for evaluating various power quality parameters are available. These templates are updated and expanded with each software update to stay current. Additionally, you can create your own templates and save them in the list or base them on an existing template.

Each template can be applied to one or more devices to generate reports with the corresponding threshold values. You can also work with threshold sets in analyses and use them as templates, or use threshold sets for event-based monitoring.

  1. Using Templates in Analyses and Event-Based Monitoring

ReportingTemplates

Currently, the following standards and threshold sets are supported:

To view the thresholds of a template, simply click on the corresponding name of the standard or threshold template. A detail window will open with the relevant information.

Using the free text search, you can search for standards or categories such as countries or continents.

Standard templates can be applied directly to devices and individually adapted to customer-specific requirements.


6.7.1. Adding Custom Threshold Sets

Adding Thresholds

Clicking "+ Add" #1 opens a wizard for adding or configuring your own template. You can select the following modes:

After selecting the mode, you enter the template name and description in the next step #3.

Template Editor

Explanation and usage of the individual sections:

6.8. Power Quality Standards (limits uharm)

This standard template includes the most common power quality parameters and their thresholds. It can be applied to all devices that record power quality data. This is also possible afterwards, even if the measuring device was previously operated with another template. The template can also be used in analyses to display the thresholds in the charts.

The template has the following parameters in the General section:

Thresholds for Power Quality Standards

The selected reporting template also affects the generated print output:

For report branding and page format, WebPQ additionally uses the report settings of the current tenant:

6.9. Fault Ride Through (FRT) Curves

An FRT template describes permitted or violation regions over residual voltage and duration. Use Create threshold group and choose Custom FRT limits as Type of threshold to create to create a template directly in the current profile format. Select an existing template by name to edit it.

Enter each named region as a closed path containing at least three points:

To use Only when a voltage-duration profile triggers in a fault-record task, select the Fault Recording evaluation method and ensure every region is a valid closed path. A PQ Events profile can be used in analyses but is not eligible for this fault-record filter.

6.9.1. Custom Curves After an Update

An older custom curve opens as an unsaved repair draft in the current editor. Review its regions and electrical context before saving. The current polygon format closes each boundary between its last and first points; use +, the bin button, point ordering, and ∞ to correct the resulting area. An empty old region offers Add Point so it can be rebuilt instead of forcing the complete template to be recreated.

If an older curve contains negative durations or voltage percentages, the repair draft marks the affected fields and displays validation errors. Correct these values and any invalid geometry before using Save or Save Copy. Opening the curve does not automatically correct its stored values.

Opening the curve or updating WebPQ does not persist a conversion. The editor indicates that one save is required, and canonical validation must accept every region before Save is available. Only that explicit save confirms the repaired geometry, stores it in the current profile format, and makes an eligible Fault Recording profile available for fault-record filtering. If the intended regions can no longer be determined from the old boundary lines, create a new FRT curve instead.

Malformed or invalid data in a profile already stored in the current format displays an error instead of opening an empty legacy repair draft. The stored data remains unchanged; neither Save nor Save Copy is offered in this error view.

Using the template in an analysis is described under FRT Curve Analysis.


6.10. Customer-Specific Thresholds – Measurement Monitoring

This feature can be used to work with customer-specific thresholds in analyses or event-based monitoring.

Thresholds Settings

The following parameters can be set:

Name sets the template name to find it in analyses and event-based monitoring of automation tasks. Unit sets the unit for the template, e.g., V, A, kW, kVAr, Hz, etc., to which the threshold refers. Data classes sets the data class for the template, e.g., "Voltage", "Current", "Power", etc., to facilitate assignment of measurements. Multiple data classes can be selected that match the chosen unit. Devices sets which devices the template should be available for. Multiple devices can be selected. Minimum lower threshold for triggering Maximum upper threshold for triggering Absolute sets whether the threshold is considered as an absolute value or with sign Hysteresis sets how far the value must fall below or exceed the defined threshold for retriggering

Click Save to add the template to the list of available templates and apply it to the relevant devices. Click Remove to delete the template.

Thresholds can then be used in analyses – see Thresholds in Analyses – and for event-based monitoring – see Automation Tasks.

Example Use Case:

As a grid operator, I want to monitor local substations and the feeders of a grid area for compliance with EN50160, and also be notified by the system when the current reaches 90% of the NH fuse rating.

The procedure is as follows:

  1. Add several customer-specific threshold templates – e.g., with the name of the fuse size and the definition of the current value at 90% of the NH fuse

NH - Fuse

Info: Customer-specific thresholds can also be added in the device settings under the "Thresholds" tab. This allows the template to be applied directly to the device, rather than via device configuration. This is especially useful if the template should only apply to a single device or if you want to control which devices use the template.

  1. Create a dashboard for automated reporting with custom analyses and time selection

  1. Add an automated report in Automation Tasks as event-based monitoring

Automation task with custom threshold triggers for report notifications

  1. Result

If the defined thresholds for one or more devices are exceeded, the recipient automatically receives a notification with the freely configured dashboard as a PDF via email.

6.10.1. Printed Report Behavior

Generated reports and print views are prepared server-side. WebPQ waits until the included charts and report elements have finished loading before the PDF is created. During that preparation, the report page shows a loading state instead of exporting a partial page.

For EN-style table reports, WebPQ uses a dedicated print mode:


6.11. Reporting - Automation & Tasks

A central feature of WebPQ is the automated, targeted provision of information for various users or applications. For this purpose, the software has a module for task automation.

A key advantage of the software is its ability to regularly and automatically generate compliance reports, such as those according to EN50160 or VDE-AR user guidelines. Additionally, the software can automatically inform affected customers in the event of network disturbances. In many use cases, the software solution also requires the automatic storage and export of measurement data in open file formats. All these settings and tasks can be configured and managed in the "Tasks" section.

The main tasks enabled by the software's automation functions are listed below:

1. Fault records This module allows automatic alarm notifications to be sent or fault records to be stored, for example, in the event of power grid disturbances. Notifications can be sent via email and include all relevant information about the disturbances. This ensures that users or system administrators are directly and efficiently informed, enabling a quick response to network issues.

2. Reports This function allows standard reports to be created and sent regularly and automatically. Examples include reports according to the EN50160 standard or other industry standards. These reports can be created in various formats, such as PDF. Additionally, the tabs created in the Analysis Dashboard can be used as a basis for automated reports. This enables regular, standardized reporting without manual intervention.

3. Export The export module allows the automatic and regular export of measurement data for one or more devices. The exported data can be stored in open file formats needed for further analysis or archiving. This function ensures that all relevant measurement data is always available in a structured and accessible format without requiring manual exports.

All these tasks and automation processes can be centrally managed in the "Automation tasks" section of the software, allowing for easy configuration and regular execution of automated processes.


6.11.1. Backup and Download of Generated Data

The complete reports and exports created in the automation tasks are stored both in the file system of the WebPQ server and in the specified folders that can be configured in the WebPQ backend. More information about the backend can be found at Link. These data can be retrieved at any time.

Additionally, the created data is also available in the "Import / Export" section under "Export" in the client and can be downloaded directly via the browser.

Download

6.11.2. Activation / Deactivation of Tasks

Each task can be activated or deactivated as needed. This allows flexible control over whether a task should be executed or not.

Activation of Tasks

6.11.3. Creating Tasks

Automation task settings with devices, tags and tag categories

By clicking the "Add Task" button, the user can create new tasks. In the first step, the task name and a description must be specified under which the task will be saved. These details are necessary to uniquely identify and correctly assign the task later.

In the next step, the type of task is determined. This type defines how the task will be executed and which specific parameters need to be configured.

Depending on the task type, the affected measurement points can be selected not only through individual devices, but also through tags and tag categories. This makes it possible to define automation tasks for logical device groups without selecting every device individually.

A typical example is a recurring report for all devices with the "highvoltage" tag. If the automation task is defined through this tag, it will automatically also apply to newly added devices as soon as they are assigned the "highvoltage" tag as well. In that case, the report does not need to be adjusted manually just because additional matching devices were added.

The practical benefit is that existing jobs do not need to be parameterized again for every newly created device. As soon as a new device is assigned to the selected tag or tag category, it is implicitly included in all matching automation jobs of this section.


6.11.3.1. Creating a Disturbance Record Task

A commonly used task is the disturbance record. This task allows for automatic notification or logging in the event of a disturbance. The disturbance record is usually sent as an email to defined recipients as soon as a network disturbance is detected. This ensures that responsible persons are immediately informed, allowing for a quick response.

Disturbance record task with device, tag and tag category selection

With #1, the task name is specified. Under #2, settings can be made regarding which devices, tags, or tag categories are eligible for sending and which reporting format (e.g., PDF or COMTRADE) should be chosen. Additionally, the type of record can be set in the settings, such as oscillographic or TRMS record (True Root Mean Square), which affects the type of measurement data representation.

The data-type selection is limited to measurements that are actually available for the selected scope. When the device, tag, or tag category changes, WebPQ updates that selection and selects the available disturbance-record types for the new scope.

Fault-record delivery can be configured in two modes:

If the selected profile or the disturbance evidence cannot be evaluated reliably, WebPQ does not send the fault record as though the task were unconditional. Check the task error and the selected profile before processing a new disturbance.

The same advantage applies here: if the selection is based on tags or tag categories, newly created and correspondingly assigned devices are included automatically. Existing disturbance-record jobs therefore do not need per-device follow-up parameterization.

In the email settings, the recipients, subject, and formats must be specified. It is also possible to include variables to create individual subject lines or email texts. This function offers high flexibility as the content of the emails can be tailored to specific requirements and circumstances.

Disturbance Record Task

In the time settings section, specific parameters can be set, such as how far back the disturbance record should be considered. This allows defining the period in which disturbances can be processed or analyzed retrospectively and determining how long historical data should be sent. Moving the start time back re-processes the matching disturbance records from that time on: a task that always sends resends them, and a task that sends only on a voltage-duration profile trigger evaluates each record again against the currently selected profile and sends only the violations.


6.11.3.2. Creating a Report Task

Using the reporting templates and the analysis dashboard, the WebPQ software offers the ability to automatically generate PDF reports according to standards from over 65 different templates. These reports can be created for device groups or individual devices.

In the automation task settings, the affected devices, tags, or tag categories as well as the report template must be selected. These templates can be customized in the reporting editor either according to standard specifications or customer-specific requirements.

This is especially useful in growing installations: when a report is defined through tags or tag categories, newly added devices become part of the existing job automatically after they are assigned accordingly, without reopening and extending the report configuration.

For more customized reports, the software offers the ability to create free reports from various types of analysis using the individually configurable tabs in the analysis dashboard. To do this, simply select the desired tab under point #2.

Virtual devices can be used only with an individually configured dashboard tab whose analyses all support virtual devices. Reporting templates and incompatible tabs keep virtual devices visible but disabled. A warning identifies an existing incompatible selection, including virtual devices included through tags or tag categories.

In the time settings section, specific parameters can be set, such as frequency, day of the week, and time at which the regular report should be generated. This function enables complete automation and scheduling of report generation without manual intervention.

For automated report emails, WebPQ supports placeholders that are filled during task execution. Depending on the task and the available device metadata, placeholders can insert values such as the report ID, report description, station ID, group, plant, field, device, recorder information, trigger time, or generated file name into the subject or body text.

Automated reports use the same generation pipeline as manual print jobs. Therefore:


6.11.3.3. Creating an Export Task

Unlike reports, the export task mainly differs in the settings. While the selection of affected measurement points is similar to reports and can also be done through devices, tags, or tag categories, the export format must also be selected here. The export allows measurement data to be stored in various formats.

Export tasks benefit from the same pattern. If the selection is made through tags or tag categories instead of single devices, newly added devices are picked up automatically as soon as they belong to the configured group.

Currently, the following export formats are available:

6.11.3.3.1. CSV

For CSV export, after selecting the format, the data class or data points to be exported must be specified. This provides the flexibility to export only the relevant data in a structured CSV format.

Only data types measured by the selected devices are offered. Newly available types are not selected automatically for a general export task.

Virtual devices are supported for CSV time-series exports with compatible historical data classes and data points. Event, binary, subsecond, disturbance-record, and status data are not available. Other automation export formats such as NeQual, PQDIF, and COMTRADE do not support virtual devices. Unsupported virtual devices remain visible but disabled; existing incompatible selections produce a warning.

Export
6.11.3.3.2. NeQual

For NeQual export, the number of weeks, the country, and the start time of the export period must be specified. These settings allow data to be exported for specific periods and geographical regions.

Nequal Export

After an automation task starts an export, the generated file also appears in the regular Import / Export > Export overview. This is where completed files can be downloaded and failed exports can be checked together with their error text.


6.12. Import of Measurement Data

6.12.1. General Information

To import measurement data into the WebPQ software, various options are available. The import can be performed either manually via the client or automatically through direct connection via TCP/IP.

A manual import is used when there is no direct connection to the measuring device or if such a connection is not desired. Additionally, measurement data from other systems or from end customers can be imported this way.

6.12.2. Manual Import

In the Import / Export >> Import section, you will find the function for manual import. This allows you to upload data that has been exported, for example, via SD card, WebServer, or WinPQ Lite.

This page describes the import of measurement data. To transfer devices that already exist in WinPQ into WebPQ, use Administration > Devices > + Import from WinPQ instead. The device import workflow is described in Devices under Importing Devices From WinPQ.

6.12.2.1. Importing PQ-Box Data

To import PQ-Box data, first select the PQ-Box import type in the import wizard. After that, choose the directory that contains the exported files.

During PQ-Box import, WebPQ processes supported .pqf measurement files and assigns their contents to the data classes used in WebPQ. Sidecar files such as parameter, info, or comment files may be present in the selected directory. Unsupported log files are not imported as measurement data.

Imported cyclic data and recorder data use the same data-class names as PQI device data. This means PQ-Box data is available consistently after import in analyses, exports, reports, and synchronization views.

6.12.2.2. Importing COMTRADE Data

To import COMTRADE data, select the Comtrade import type in the import wizard. This option is visible only when the COMTRADE import add-on is enabled in the license.

Each COMTRADE import group must contain at least a .cfg file and a matching .dat file. Optional .hdr, .inf, and .cff files are also considered when they belong to the same COMTRADE group.

On the file side, WebPQ uses the Rec-ID from the COMTRADE metadata, more precisely the identNumberOrDeviceName field, as the identifying value. This value can be used in the wizard to group related files. The actual assignment inside WebPQ, however, is not based only on this identifier. It is made in the mapping step by assigning the import to a specific COMTRADE device.

In the mapping step, WebPQ shows the channels from the configuration file. These channels must be assigned to a COMTRADE device and to the target channels in WebPQ. If no suitable COMTRADE device exists yet, create it directly from the import dialog or beforehand in device management.

If a channel mapping has already been stored for that COMTRADE device, WebPQ can reuse that mapping in later imports with matching channel names. In this context, the Rec-ID is mainly used for grouping and recognition of import files, not as a complete replacement for the device selection in the wizard.

Missing .cfg/.dat pairs, unreadable configuration files, or files with too many analog channels are shown in the wizard before upload. Warnings and import errors from the actual import run are also written to the import log.

6.12.2.3. Automatic COMTRADE Import

When an administrator has configured automatic COMTRADE import, WebPQ processes complete COMTRADE filesets from the configured import folder. The feature is disabled by default. Its default scan interval is 10 minutes, the file-stability window is 5 minutes, and the maximum combined fileset size is 512 MB. Successfully imported source files are deleted by default; administrators can retain them instead.

The state appears immediately before the COMTRADE file extension and applies to .cfg, .dat, .hdr, .inf, and .cff together:

Incomplete filesets remain unmarked and wait for the missing member instead of becoming failed after a timeout. When WebPQ can assign an incomplete fileset to a device, it allows older complete filesets for that device to import but blocks filesets at or after the incomplete fileset's first timestamp. The block remains until the missing member arrives or an operator removes the abandoned fileset. WebPQ writes a throttled warning to the system log while such a fileset blocks a device.

Automatic imports appear under Import / Export > Import for users who may read measurements for the affected device. The import type identifies them as automatic. For failed or blocked complete filesets, download the import log there to see the affected filesets and concrete reasons, including configuration parser errors. Incomplete filesets do not create an import job or import log until they become complete. Additional technical details such as filesystem errors remain in the application log. When Delete files after import is enabled, WebPQ deletes successfully imported files instead of marking them as imported.

6.12.2.4. Import Process

The manual import is carried out in several steps:

6.12.2.5. Step 1: Start the Import Wizard

Data Import

6.12.2.6. Step 1a: Select the Import Type

Select the import type that matches the source files. For PQ-Box imports, select PQ-Box before choosing the files from the SD card or export directory.

Import wizard with PQ-Box selected

For COMTRADE imports, select Comtrade. This option is visible only when the COMTRADE import add-on is enabled in the license.

Import wizard with Comtrade selected

6.12.2.7. Step 2: Select Directory with Measurement Data

Data Import Selection

Note: You must agree to the security message!

Security Warning

6.12.2.8. Step 3: Assign Measuring Devices

Device Assignment

6.12.2.9. Step 4: Upload and Import

Upload Data

6.12.2.10. Step 5: Progress and Verification

Import Overview

6.13. Export of Measurement Data

6.13.1. General

The WebPQ software offers both manual and automated export options for measurement data.

In the Import / Export > Export section, you can:

Exports are created as background jobs on the server. This means the export can continue even when larger data ranges take longer to prepare, and the result becomes available in the export overview as soon as processing finishes.

Export

6.13.2. Manual Creation of an Export

A manual export is carried out in several steps:

6.13.2.1. Step 1: Open Export Dialog

6.13.2.2. Step 2: Assign Export Name

6.13.2.3. Step 3: Choose Export Format

Tip: For the formats PDF and Comtrade, other methods for creating reports and exports are available. For more information, see Export via Burgermenue.

6.13.2.4. Step 4: Select Devices

Virtual devices can be selected for CSV time-series exports with compatible historical data. Event, binary, subsecond, disturbance-record, and status data are not available. NeQual, PQDIF, and COMTRADE do not support virtual devices; these devices remain visible but disabled when those formats are selected.

6.13.2.5. Step 5: Define Time Period

6.13.2.6. Step 6: Determine Data Classes

Depending on the selected export type, additional validation rules apply:

As long as the parameter set is incomplete or invalid, the confirmation button remains disabled.

Export

6.13.3. Export Process and Management

After all settings have been made, the export is started on the server by confirming with "OK".

While exports are in status Pending or In Progress, the overview refreshes automatically more frequently so that progress changes and completed downloads appear without a manual reload.

6.13.3.1. Export Overview and Download

The overview contains both manually created exports and files created by automation tasks. Each completed export is provided as a ZIP file, even if the selected export format inside that ZIP is CSV, PQDIF, or NeQual.

The status column shows the current processing state:

For supported formats, the New from row action can be used to open a new export dialog with the parameters of an existing export already prefilled. This is useful for repeated exports with the same scope.

Finished or obsolete exports can be removed from the table again. This deletes the export entry and the associated server-side export data for the selected rows.

If an export fails, WebPQ also writes a corresponding Syslog error entry. This makes failed exports traceable in operational monitoring in addition to the error text shown in the export table.

6.13.3.2. Note on Server Configuration


6.14. Data Synchronization (OT / IT Bridge)

Overview of the OT IT data synchronization

6.14.1. Technical Flow in WebPQ

Data Synchronization in WebPQ is implemented as a file-based one-way transfer between two separate instances. The actual transfer path between OT and IT is intentionally not handled by WebPQ itself, but by an on-site mechanism such as a data diode, rsync, scp, or a comparable secure file transfer solution.

The flow follows the implementation directly:

  1. Export on the OT system
    As soon as measurement data has been written successfully to the database, WebPQ creates one sync file per device and data class in the configured export folder. The files are stored in a folder structure following the pattern exportFolder/deviceName/dataClass/.

  2. File types and ordering
    WebPQ uses continuously numbered files. During normal operation, it creates incremental files such as device-dataclass-sequence.aed or, when compressed, ...aed.snappy. For full snapshots it creates ...full.aed or ...full.aed.snappy. For additive historical gap backfills it creates ...historical.aed or ...historical.aed.snappy.

  3. Unidirectional transfer
    These files are copied from the OT sync folder to the IT sync folder. Because WebPQ itself does not require a return channel, this transfer path can be operated with strictly unidirectional security components.

  4. Import on the IT system
    The import process scans the configured import folder every 15 minutes for new device-data-class combinations. For combinations that are already known, it then checks every 10 seconds whether the next expected file number is available.

These two intervals are currently part of the fixed OT/IT bridge implementation. They are not exposed as separate export/import settings in the WebPQ administration interface and therefore cannot be adjusted directly by a user.

  1. Completeness and ordering checks
    A file is processed only after WebPQ detects that it is complete and finalized. WebPQ then imports files strictly in file order. A full file replaces the current data set on the target system for the affected device/data-class combination. historical files and normal incremental files are imported additively.

  2. Automatic device creation on the target system
    If the device does not yet exist on the IT system, WebPQ creates it automatically on the first successful import as an offline device, with the description Imported via data sync and the tag syncimport. This keeps imported synchronization devices easy to identify in administration views.

  3. Synchronized contents
    In addition to the measurement rows, WebPQ also transfers the technical metadata required to interpret them correctly, such as data-class assignments, time-zone information, recording configurations, and device hierarchy data. OT-side connection details such as IP addresses are not exported.

6.14.2. General

The Data Synchronization (OT / IT Bridge) feature writes measurement data automatically into a file when it is stored in the database. This file can then be transferred by third-party tooling such as rsync, scp, or data diode solutions to another server, where a second WebPQ instance can import it. This enables secure OT-to-IT data communication without a return channel and preserves strict network separation. The synchronization files contain measurement values plus measurement metadata such as timestamps and device names, but not OT-sensitive connection details such as IP addresses. Data Synchronization supports both one-time and continuous synchronization. It can also be used for measurement-data backups, but it does not replace a full database backup.

Why use data synchronization with unidirectional transfer?

Secure separation of OT and IT systems is essential in critical infrastructure environments such as energy, water, and manufacturing. Data diodes and similar one-way transfer solutions are often not optional, but mandatory:

Data Synchronization supports both one-time and continuous synchronization. It can also support measurement-data backups, but it is not a replacement for a full database backup.

6.14.3. Technical Requirements

For Data Synchronization (OT / IT Bridge) to work, the following technical requirements must be met:

File system and access:

Storage capacity:

File management:

6.14.4. Setting Up Data Synchronization

Data Synchronization (OT / IT Bridge) is configured via the administration interface of the WebPQ instance. The settings for export and import can be configured there separately. It is also possible to filter the selection of devices using a regular expression so that, for example, only specific devices are synchronized.

Administration interface

To make selecting the devices to be synchronized easier, regular expressions can be used. For example, the regular expression .* can be used to synchronize all devices, or Plant.* can be used to synchronize only devices whose name begins with "Plant".

Attention: The screenshot is provided only to illustrate the Data Synchronization (OT / IT Bridge) settings. Exporting and importing data at the same time on the same WebPQ instance is not possible, because the devices are detected there as already existing and the synchronization does not start. Therefore, it is important to set up synchronization on two different WebPQ instances in order to ensure that the functionality works correctly.

6.14.5. Licensing

Data Synchronization (OT / IT Bridge) is a special feature that is generally not included in the standard license. It requires a separate license because it involves additional resources and maintenance effort. Measurement data synchronization will only start if a valid license for this feature is available. Without the corresponding license, the synchronization processes will not start and no data will be synchronized.

For operating the OT/IT bridge, the license WebPQ Add on Second Instance-OT/IT Bridge with article number L.900.9265.39 must be available. This license prerequisite should be verified for the WebPQ instances involved so that data-sync export and import are enabled technically.

6.14.6. Synchronization Status

The status of Data Synchronization (OT / IT Bridge) on the source system can be monitored using log files that contain information about possible errors. If export is not possible - for example because the file system is full - this is recorded in the log file as a syslog message. It is therefore important to check the log files regularly in order to ensure that the synchronization works smoothly and to detect possible problems at an early stage.

In practice, it is useful to distinguish between syslog events and log files:

In the Electron desktop application, an administrator can open these folders directly from the syslog page. In the browser, the log files can be downloaded there as a ZIP archive. For OT/IT bridge troubleshooting, the syslog inside WebPQ is usually the most important first stop.

On the target system, the synchronization status can be viewed on the "Device Synchronization" page in the "Import / Export" section. The current synchronization status is displayed there, including information about the last synchronized files and possible errors. Further details on the synchronization status can be found in the documentation under Synchronization Status. Syslog messages are also logged on the target system if import is not possible - for example because the files cannot be read or because the database has changed and is no longer in the same state as during export. Therefore, it is also important on the target system to check the log files regularly in order to ensure that synchronization works smoothly and to detect possible problems at an early stage.

The status page is refreshed regularly. It shows whether synchronization is active for a device, whether errors are present, when the latest synchronized data point arrived, and whether files are currently still waiting in the upload queue.

6.14.7. Synchronization Details

Export is triggered directly from the measurement-data write path. WebPQ therefore writes the sync files only after the corresponding block of data has been stored successfully in the OT database. This ensures that the exported file is always based on a consistent data state.

The import process works in two cycles: every 15 minutes, it looks for new device-data-class combinations in the import folder. For combinations that are already known, WebPQ then checks every 10 seconds whether the next expected file is present. Only files that have already been written completely and finalized are imported.

The meaning of the file types is important:

All devices created automatically by synchronization receive the tag syncimport so that they can easily be distinguished from other devices. This tag can be removed or changed later if it is not needed.

6.14.8. Automatic deletion of imported files

By default, the target system does not remove any files from the import folder; it only keeps track internally of which file to import next per device and data class. Managing the import folder is therefore left to the operator.

For environments where the customer cannot manage the folder on the target system themselves, WebPQ can be configured to delete each successfully imported .aed file automatically, immediately after the import. This is enabled through the deleteFilesAfterImport setting on the target system.

Note on full snapshots and restarts: Only files that were actually imported are deleted. When a full snapshot is imported that supersedes older incremental files for the same device/data-class combination, those older, skipped files remain in the import folder. Because the import progress is held in memory and re-derived from the files present on startup, a restart after the full snapshot has been deleted can cause the oldest remaining incremental file to be imported additively (without the data reset of the full snapshot). Therefore, when deletion is enabled, feed the import directory through a forward-only synchronization (for example the rsync flow described below) and avoid mixing a full snapshot with stale older incremental files.

6.14.9. Synchronizing the shared folder with rsync

When the export and import folders are not the same directory but are mirrored across a one-directional transfer path between the OT and IT zones, rsync is the recommended tool to copy new .aed files from the export side to the import side. The directory layout ({device}/{dataClass}/{device}-{dataClass}-{number}.aed) is preserved verbatim by a recursive copy, so the target system finds the structure it expects.

A typical one-directional copy from the export folder to the import folder looks like this:

rsync -a --ignore-existing /path/to/export-folder/ /path/to/import-folder/

Guidance:

6.14.10. FAQ and Troubleshooting

6.14.10.1. What can I do if no data arrives in the IT system?

Check the following points in order:

  1. Verify that data synchronization is licensed on the source and target tenant. Without the DataSync feature, export or import remains disabled and no files are processed. For the OT/IT bridge, this includes the license WebPQ Add on Second Instance-OT/IT Bridge with article number L.900.9265.39.

  2. Verify that the configured export folder on the source system and the import folder on the target system really exist and are directories.

  3. Verify that the source system has write permissions and the target system has read permissions for the shared folders.

  4. Verify that the source and target systems are two different WebPQ instances. Import and export on the same instance is not the supported setup for this workflow.

  5. Verify that the configured device filter regular expression actually matches the expected device names.

  6. Check the Device Synchronization page on the target system and the Syslog on both systems.

6.14.10.2. What should I look for in the Device Synchronization page?

The page gives the fastest overview of whether the target system is still catching up or whether it is blocked:

If the queue warning stays visible for a long time, this points to a backlog in database upload processing on the target system.

6.14.10.3. Which errors are reported directly by WebPQ?

The code paths for synchronization write explicit operational messages for several important failure cases:

These messages are written to the Syslog and should be checked first when synchronization stops unexpectedly.

Examples of actual messages from the implementation are:

When such messages appear, the first checks should be the configured folders, permissions, license status, and file readability.

6.14.10.4. Can the synchronization intervals be adjusted?

For the OT/IT bridge, not through the normal export/import configuration. The current behavior is fixed as follows:

At the moment, the OT/IT bridge exposes only these settings in the user/admin interface:

This should not be confused with device synchronization between a measuring device and the WebPQ server. Those intervals can be adjusted administratively in the instance settings and are described on 6_6_4_synch.md. Changing those settings does not change the 15-minute or 10-second OT/IT bridge file-processing cycles.

6.14.10.5. Where exactly are the logs located?

Depending on the use case, in two places:

  1. WebPQ syslog inside the application
    The functional OT/IT bridge messages are shown in the application's syslog view. For first-level troubleshooting, this is usually more useful than raw file logs.

  2. Standard server log files
    By default under %PROGRAMDATA%\aeberle\logs\services. If the instance uses a different persistent data path, the effective path is <persistentDataPath>\logs\services.

  3. Audit log files
    By default under %PROGRAMDATA%\aeberle\logs\audit, or under <persistentDataPath>\logs\audit if a custom persistent data path is configured.

From the syslog page, an administrator can open these folders directly in the desktop application or download their contents as a ZIP archive in the browser.

6.14.10.6. What if the target system shows an error for a data class?

Open the device in Import / Export > Device Synchronization and inspect the detail view:

This is the intended recovery path when the target system knows which data class is blocked and the source files are still available.

6.14.10.7. What if the queue on the target system does not decrease?

If the synchronization page shows many files waiting in the upload queue for a longer period, this indicates that the target system is importing slower than files arrive. In this case:

  1. Check whether the warning about too many files in queue remains visible.

  2. Check the Syslog for repeated import errors.

  3. Check whether storage, database performance, or administrative limits are slowing down the upload pipeline.

  4. If necessary, ask an administrator to review the system setting for maxParallelUploads.

6.14.10.8. What if files exist on disk but are still not imported?

The target system scans the import directory periodically for new device-data-class combinations and then continues to check for the next expected file. Because of this behavior, the following points matter:

6.14.10.9. How can I distinguish synchronized devices from locally created ones?

Devices created automatically by the synchronization import receive the tag syncimport. This makes it easier to recognize imported devices during troubleshooting.


6.15. Reports and Printing

All reports generated by users as PDFs can be found in the "Import / Export >> Print" section. Here you can view, download, and manage the reports.

Reports generated through the following functions can be found there:

The PDF files are stored on the server in the directory specified in the WebPQ backend. On the client, the reports are displayed in a table containing the following information:

TitleTypeTimeActions
Name of the reportType of report (e.g., automation task)Time of report creationDownload the report
Print

By downloading the report #1, the user has the option to download the PDF from the server and save it locally.

With #2, the user can select multiple reports. Via #3, the user can either download multiple reports in parallel or delete multiple reports via #4.


6.16. Synchronization Status

Measuring devices that are continuously read out automatically by the database software are displayed in the "Import / Export" section under "Device Synchronization".

The exact status of the synchronization is shown there.

The page displays the following information, which can be expanded with details for a measuring device by clicking on #1. Additionally, a hierarchical view can be selected via #2. The table itself contains the following information:

Device NameRegular SynchronizationActiveCurrent Error StatusLatest Synchronized Data Point
Name of the device, including tag displayIndicates whether the device has been enabled for regular synchronization in the settingsShows the current statusDisplays the current error statusShows how recently measurement data reached the database

Synchronization Status

6.16.1. Details of the Synchronization Status

6.16.1.1. Device Synchronization

Device synchronization displays the download status from the device to the server. In addition to the current synchronization status, such as "Inactive", the following information is also shown:

If, for example, there is a connection issue with the measuring device, this error will be displayed under "Device Synchronization Error".

6.16.1.2. Database Synchronization

Database synchronization shows the upload status from the WebPQ instance to the database. Here, the individual data classes are listed, along with the files that were last uploaded to the database. The section "End timestamp for the most recent file" displays the timestamp recorded as the last measurement point in the most recently uploaded file.

Additionally, users have the option to selectively check data classes to see which data was last uploaded to the database.

Synchronization Status Details

If the user wants to change the settings for a measuring point, he can directly switch to the configuration of the measuring point by clicking on Settings #1. Additionally, #3 allows for expanded logging to obtain more information. This function is sometimes used in the support area upon request.

6.16.1.3. PQID Synchronization

Smart and PQID devices are listed together. For a PQID device, the detail view shows its connection, whether regular synchronization and a readout are active, the last completed and last successful readout, the latest error, and the newest database timestamp for each configured data class. PQID timestamps are displayed without the Smart-device age coloring because PQID connections do not provide the same expected synchronization interval.

The Logs tab shows the read-only PQIDDataImportAPI.log for the device's PQID connection and continues to append new content while it is open. Devices that share a connection show the same connection log. If no connection or no log file is available, the page displays a corresponding message.

6.16.2. Synchronization Intervals and Data-Class Priority

Automatic device synchronization checks active devices repeatedly. A quick check normally runs every 30 seconds. A more thorough check normally runs every second quick-check cycle, so with the standard settings it runs about every 60 seconds. These intervals are configured by the system administrator in the WebPQ instance settings.

When several data classes are waiting for download or upload at the same time, WebPQ processes them by data-class priority. Fault recorder and long-term classes are prioritized before lower-priority classes. This helps important disturbance and EN 50160 data arrive before less urgent data when a device or database has a larger backlog.


6.17. Administration

6.17.1. Devices

6.17.1.1. Overview and General Information

Through the Device Management, devices can be viewed, added, managed, and deleted.

The interface is divided into three sections:

  1. Add and delete devices

  2. Tabular and hierarchical representation of all existing devices

  3. Detailed device view, which is displayed after clicking on a device under #5

Device Settings

All functions require the permission "Create and delete devices",
which is configured in the rights management at the user group level.

Additional Functions

Operation with WinPQ in parallel mode

When the WebPQ software is operated together with the WinPQ software, the following measuring devices are automatically transferred from WinPQ to WebPQ after installation. An automated synchronization occurs in the background every 60 seconds. These devices are then added to the user group root_default_users, root_default_operators, root_default_administrators, and the root tenant.

For these measuring devices, WebPQ serves as a pure visualization solution based on the measurement data read out and stored in WinPQ via the PQ Manager process.

For the device generations PQI-LV, PQI-DA smart, and PQI-DE, which are used in parallel operation with WinPQ, the process of transferring the communication layer from WinPQ to WebPQ is partially automated. This can be done via the button +Import from WinPQ.


6.17.1.2. Adding PQI-D Devices

PQI-D devices are added with the same + Add new device wizard as other measuring devices. The PQI-D workflow differs from PQI-DA smart, PQI-LV, and PQI-DE because WebPQ first connects to the PQI-D communication endpoint and detects the measuring devices that are available behind that connection.

PQI-D device creation is available only when WebPQ runs on a Windows server. On other server operating systems, the PQI-D device types are hidden in the device type selection.

To add a PQI-D device:

  1. Open Administration > Devices.

  2. Select + Add new device.

  3. Select PQI-D UI or PQI-D UU as the device type.

  4. Select the device time zone and tenant.

  5. Enter the PQI-D connection data:

  6. Click Get Devices.

  7. Select the detected devices that should be created in WebPQ.

PQI-D device creation connection step

After the devices have been detected, choose the data classes that WebPQ should read automatically. WebPQ preselects the data classes needed for EN 50160 evaluation. The Active switch controls whether the automatic data download is active for the detected device.

PQI-D device creation data class selection

When a PQI-D UU device exposes two voltage systems, WebPQ creates the related subdevices from the detected device list. For license counting, the related PQI-D UU pair is treated as one device unit.

6.17.1.3. Importing Devices From WinPQ

The Import WinPQ Devices wizard is intended for systems that already contain devices in a WinPQ installation. It imports the device metadata into WebPQ and supports the transfer of PQI-DA smart, PQI-LV, PQI-DE, and PQI-D devices where the communication layer can be moved into WebPQ.

Use this wizard when devices already exist in WinPQ and should be managed or read directly by WebPQ. After the import, review the detected devices before creating them. Device names, connection settings, and data classes should be checked carefully because they determine how WebPQ stores the imported measurement data and how the devices appear in analyses, exports, and dashboards.

6.17.1.4. COMTRADE Import Devices

COMTRADE imports use WebPQ devices of type Comtrade. This device type is available only when the COMTRADE import add-on is enabled in the license.

A COMTRADE device stores the target channel mapping used by the import wizard. The mapping links channel names from the COMTRADE configuration file to WebPQ data classes and data types. Check the time zone and channel mapping before running regular imports from the same source, because the settings are reused when matching COMTRADE files are imported again.

6.17.1.5. Detail Window

When the detail window is opened by clicking on one or more selected devices in the selection field, the detailed settings of the devices appear.

General

General #1 In the General section, configure parameters such as IP address, device time zone, and tags. Assign threshold templates under Thresholds.

Connection #2
In the Connection section, in addition to the IP address, the settings for the automatic data class readout process can be managed and their activation and deactivation controlled.
When multiple devices are selected in parallel via the device tree, the tabular and searchable representation allows for quick parameterization and comparison of many devices.

Parameter #3
In the Parameter section, the measuring device parameters can be individually adjusted. This allows the measuring devices to be centrally parameterized directly via the web interface.
All parameters are historized in the database. Various parameter editors allow the application of parameter templates to devices, editing of individual parameters, and importing and exporting parameters – either directly to the measuring device or to the local file system.

Measuring site parameters In the Measuring site parameters section, grid connection powers and calculation factors for current grid-code analyses can be viewed and, with metadata edit permission, changed.

Service #4
In the Service section, all functions necessary for device service are summarized. These include, among others:

Rights #5
In the Rights section, the effective permissions of users for the respective devices can be viewed via rights management and group policies.

NeQual #6
If licensed, the NeQual section allows the configuration of settings for the NEQUAL export once per measuring point.


6.17.1.6. Device / General

General
6.17.1.6.1. Database ID and optional device label
Device label

Every device in WebPQ has a database ID and can also have a device label:

Important: Changing the device label only renames a device visibly – measurement data, historical data, and stored device references stay linked to the database ID. When labels are identical, the device information attached to the displayed name identifies the device unambiguously by its database ID.

6.17.1.6.2. Device information on display names

Where a device name appears as an interactive display name, hovering over it or focusing it with the keyboard opens a device information card. Alongside the display name, it shows the device type and database ID; a configured device label appears separately. Depending on the device and available data, it may also show the description, time zone, address, location, and assigned or inherited tags. For a child device, it also shows its parent device. Use the database ID on the card to distinguish devices with identical or similar display names.

Device information card with connection status

For supported devices, the card also provides shortcuts to the device user interface, report, and parameterization. The device user interface opens directly in the user's browser, which must be able to reach the device's web server. For device types whose URL WebPQ determines, the WebPQ server also needs access to port 443 (HTTPS) or, if necessary, port 80 (HTTP). Check both communication paths; prefer HTTPS and approve HTTP only with a documented exception. See the communication matrix and port approvals in the IT security handbook. Connection status appears at the bottom when available. The fields and actions shown depend on the device type and the current view. The question-mark icon on the card opens this documentation section directly.

To choose how device names are displayed for your account, see Application Settings: Device display names.

6.17.1.6.3. Practical examples: naming the main device and feeder measurements

Example 1 – Name the main device measuring the transformer

A PQI-DA smart measures transformer T101 and was created with the database ID pqida012 (immutable). Via the device label it becomes the display name "Transformer T101". The copy control can also reuse an existing tag value (e.g. the value of the Field category). As a result, "Transformer T101" appears in device selectors, tables, analyses, and reports, while all measurement data stays bound to pqida012.

Example 2 – Name the Modbus slaves measuring the feeders

The main device measuring the transformer has several feeder measurements connected as Modbus slaves (characteristic P3; the mbMaster must be enabled in the data class, see Device / Connection). Each slave is a child device of the master. In layouts that include the name, the master is shown alongside the slave as part of the hierarchy. To name them clearly and uniquely:

Modbus slave management with Name field
  1. Reuse the name from the parameter set (no retyping). The name configured for a slave in the main device's parameterization under Device / Parameter, in Modbus slave management (field Name), travels with the measurement data. On the next import of measurement data, WebPQ writes it automatically onto the slave's Assigned Slave Name system tag. So after an upgrade you do not re-enter it – just make sure fresh data of the slave is imported, and the configured name reappears.

  2. Make the display use it. In your Application Settings, set the fallback order to Device Label, then name from device tags, then ID – only then is the Assigned Slave Name tag considered.

  3. Priority – leave the slave label empty. The display name is resolved as device label → Assigned Slave Name tag → database ID. A manually set device label always wins over the automatic name from the parameter set. If you want the configured name to come forward by itself, clear any old manual label on the slave; set a device label only when you deliberately want to override it (e.g. "Feeder A1").

  4. For a system-wide unique feeder reference, create a dedicated tag category and enable both unique tag assignment and single tag per device (e.g. Feeder ID or GIS ID). Assign exactly one tag per slave – see Device Tagging.

  5. Give the main device the device label "Transformer T101". Set your layout to Hierarchical name with separators, variablePlant, and separator/ → display e.g. "Substation North / Transformer T101 / Feeder A1".


6.17.1.7. Device / Virtual device

For a virtual device, select its member devices here. WebPQ combines their measurements into a virtual device. Check the warnings about different time zones of the member devices; devices managed automatically or with inaccessible members cannot be edited here manually.


6.17.1.8. Device / Connection

Connection

6.17.1.9. Device / Parameter

Parameter

Two parameterization paths:

  1. Directly in WebPQ (PQI-DA smart, PQI-DE, PQI-LV):
    Fully supported natively in WebPQ, including parameter management and historization.

  2. Via ParaExpress software (classic-platform devices such as PQI-D UI, PQI-D UU):

Parameter Container



6.17.1.10. Device / Measuring site parameters

The Measuring site parameters tab is available for device types that can provide the data needed for current grid-code calculations. It contains the grid short-circuit power, grid connection power, high-voltage reference and fictive power, and the factors used by the current harmonics limit calculation.

The tab can be opened in read-only mode by users who can access the device settings. The input fields and save action are enabled only when the user has permission to change device metadata. This allows users without edit rights to inspect the values that influence analyses such as Current Harmonics Analysis, while preventing unauthorized changes.

When multiple supported devices are selected, WebPQ shows shared values directly and marks differing values with an em dash placeholder. Saving a changed field applies that changed value to the selected supported devices.


6.17.1.11. Device / Logbooks

View logbook events from supported devices, filter them by time range, and display them in a selected time zone. Depending on the device, you can synchronize or import logbooks and export entries as CSV.


6.17.1.12. Device / Users

For supported devices, manage device-local users and roles here. These device accounts are separate from WebPQ user accounts and the WebPQ permissions shown under Rights.

Users: View and manage device accounts and their role assignments.

Roles: Manage device-local roles and their permissions.

Effective permissions: Inspect the device permissions resulting from assigned roles.

Effective permissions of service users: In support mode, inspect permissions of device-local service users.

Templates: Manage templates for device-local users and roles.


6.17.1.13. Device / Certificates

For supported REG-DN devices, view device certificates and their validity, and upload or refresh certificates on the device. These operations require a device connection and the appropriate permissions.


6.17.1.14. Device / Service

Service

6.17.1.15. Device / Thresholds

Threshold templates and groups for a device

The threshold sets assigned here are saved as a default on the device in WebPQ. All users working with this device use that default in analyses and statistics without choosing a template each time; an explicit override in an analysis remains possible.

With the Device template, WebPQ reads the device's thresholds again during every data readout. Changes to the device settings are thereby stored in the WebPQ database and remain traceable historically. Keep the thresholds configured on the device accurate and up to date.

For consistent statistical evaluations, you can instead assign a centrally maintained threshold set from the database. This does not change the thresholds on the device: if the two sets differ, the device and WebPQ may produce different evaluation results. Reports with threshold evaluations identify the threshold set used. The set used in an analysis can also be shown in the level-time diagram to compare measurements with their limits directly.


6.17.1.16. Device / Rights

Rights

In this tabular display, all users with rights on the device are shown – including:

The settings for user rights on devices are made via:


6.17.1.17. Device / NeQual

Nequal

If a NeQual license is available, general settings for the export must be configured per measuring point.


6.17.1.18. Device / COMTRADE mapping

For COMTRADE devices, assign a file or reusable channel-mapping template here and set whether the device participates in automatic import. A file can be assigned to only one device; templates may be shared. Manage other mappings under Settings > Mappings.


6.17.1.19. Device / Binary channels

For supported devices, inspect the names and descriptions of binary channels and edit them when permitted. For COMTRADE devices with an assigned file or template, these mappings come from that source and are shown here read-only; edit them through the COMTRADE mapping.


6.17.2. Fleet Management

With Fleet Management, many devices can be managed in parallel.
This requires at least WebPQ Professional with the additional license "Fleet Management" or WebPQ Enterprise, which includes this function by default.

This function significantly facilitates the management of many measuring devices and enables more efficient use of working time. Especially in the area of patch management and security updates, fleet management offers great advantages.

Fleet Management

6.17.2.1. Access and Permissions

Fleet management can be found under "Settings > Fleet Management".
The permission "Device Management" is required for use.

6.17.2.2. Functions of Fleet Management

Three central functions are available:

  1. Download the current parameter file

  2. Transfer an existing power quality standard template to multiple devices

  3. Firmware update for multiple devices simultaneously

  4. Send individual parameters to many devices

The user is guided through the first three functions by a wizard that facilitates all necessary steps.
At the end, the task is handed over to the server, which executes it in the background depending on the selected devices.

Logging out does not interrupt the job!

Each task receives a unique name, which is then displayed in a clear table with the respective status.

For the fourth option – "Send individual parameters to many devices" – access is via a device using the export function.
Detailed information can be found under Devices >> Parameterization.

Fleet Management Status

6.17.2.3. Job Management and Error Handling

Fleet Management Status

6.17.3. Access Concept with Users and Rights

Access is regulated by users, devices, tenants, device groups, and permissions. Users, devices, and device groups are "owned" by a tenant. Additionally, each user can have permissions for specific devices. They can only interact with objects that belong to their tenant and for which they have the necessary permissions.

Starting with WebPQ V2.1, the WebPQ application will also feature an LDAP interface that enables importing and synchronizing users and groups from an LDAP directory (e.g., Microsoft Active Directory). This allows you to centralize user management and enhance security. For more information, see the chapter LDAP Integration.

6.17.3.1. Permissions

Every data access to users, devices, or tenants requires a permission. For example, to read the measurements of a device, the user and the device must be granted the "Read Measurements" permission.

A permission can be valid for all objects within a tenant or only for a single device. To distinguish between these two types of permissions, we call them tenant permissions or device permissions.

Tenant Permissions

Device Permissions

Permission States

Sometimes it is not enough to just grant a permission. If you want to grant a permission to your colleague, you must also be authorized to grant this permission to someone else. In this case, the permission must be in the state "can grant" or "fully granted".

The four states in which a user's permission can be are as follows:

Device Permissions are Granted in a Three-Tier Model:

All permissions are positive. This means that if a user is granted a permission on a device by a user group or directly, this permission cannot be revoked by another user group.


6.17.3.2. User Management

6.17.3.2.1. Adding a User

This function requires the "Create Users" permission.

6.17.3.2.2. Changing User Properties

This function requires the "Change User Metadata" permission.

6.17.3.2.3. Deleting a User

This function requires the "Create and Delete Users" permission.


6.17.3.3. User Groups

User groups are used for easy administration of many devices. The WebPQ software has three standard user groups:

6.17.3.3.1. Setting Up a User Group

To use this function, you need the permission to change permissions on any tenant device in your tenant.


6.17.3.4. Tenants

License Required

Tenants are used to isolate resources (users, devices) through administrative rights and data storage. The global settings for tenant management are also defined in the tenant settings. These settings are:

6.17.3.4.1. Creating a New Tenant

This function requires the permission to create and delete sub-tenants.

6.17.3.4.2. Deleting a Tenant

This function requires the permission to create and delete sub-tenants.

Only tenants without assigned users and devices can be deleted.

6.17.3.4.3. Password Policies

This function requires the permission to change tenant settings.

Note on Default Password Policies

If the password policies for a tenant are deactivated, the default password policies will automatically apply.
These default values are configured as follows:

6.17.3.4.4. Email Settings

This function requires the permission to change tenant settings.

Using the Test Email function, you can send a test email to the specified address.

6.17.3.4.5. Report Settings

This function requires the permission to change tenant settings.

Here, the logos for the reports are globally defined for the tenant.


6.17.4. LDAP Integration

Note: This feature is available in the Enterprise Edition starting from WebP V2.1.

LDAP integration allows you to import and synchronize users and groups from an LDAP directory (e.g., Microsoft Active Directory). This enables centralized user management and simplifies user administration.

6.17.4.1. How LDAP Integration Works

After enabling LDAP integration, users can log in to WebPQ directly using their LDAP credentials (username and password). Authentication is performed via the connected LDAP server. On first login, users are automatically assigned to the WebPQ group root_default_users.

Each LDAP user is counted as a separate unit and is included in the license calculation—licensing for LDAP users is identical to regular users.

Note: Automatic synchronization of LDAP groups is currently not supported. All LDAP users are added exclusively to the root_default_users group. Permissions for LDAP users must be assigned manually via groups in the WebPQ application, as the LDAP server cannot manage application-specific permissions.

6.17.4.2. LDAP Configuration

Basic Settings LDAP integration is configured in the WebPQ backend under Settings > LDAP. The following settings are available:

LDAP Search Settings:

Note: Some LDAP servers have case-sensitive attribute names. For example, cn and CN may be treated differently. Make sure to write the attributes exactly as they are stored on the LDAP server.

User Properties Mapping: Use the test function below to view all available LDAP properties from your LDAP server.

With Test Connection, you can test the connection to the LDAP server and verify if the configuration is correct. With Save, the settings are applied.

Test Username (testing only): Enter a username to test the LDAP search.

Test Result: Displays the results of the LDAP search for all parameters. If the user is found, the mapped attributes are shown.

LDAP settings page with test results

6.17.5. OAuth Integration

Note: This feature is available in the Enterprise Edition starting from WebPQ V2.1.

OAuth integration allows you to use an external OAuth 2.0 / OpenID Connect provider (e.g., Microsoft Entra ID, Keycloak, Okta) for user authentication in WebPQ. This enables single sign-on (SSO) and centralizes identity management with your existing identity provider.

When OAuth is enabled, the login page will display an additional button allowing users to authenticate via the configured OAuth provider:

Login with OAuth

6.17.5.1. How OAuth Integration Works

After enabling OAuth integration, users can log in to WebPQ by clicking the OAuth login button on the login page. They will be redirected to the configured OAuth provider for authentication. Upon successful authentication, users are redirected back to WebPQ and automatically logged in.

If autoRedirect is enabled, WebPQ redirects users to the OAuth provider automatically when they open the login page. The regular login page is then only shown again if WebPQ has to display an OAuth error message or after an explicit logout.

On first login, OAuth users are automatically created in WebPQ and assigned to the root_default_users group. Each OAuth user is counted as a separate unit and is included in the license calculation—licensing for OAuth users is identical to regular users.

On later logins, WebPQ compares the returned OAuth user data with the locally stored OAuth user and updates the stored first name, last name, and email address if they changed at the provider.

Note: Automatic synchronization of groups from the OAuth provider is currently not supported. All OAuth users are added exclusively to the root_default_users group. Permissions for OAuth users must be assigned manually via groups in the WebPQ application.

If a local non-OAuth user already exists with the same username, the OAuth login is rejected. The same applies if an existing OAuth user is found with the same username but a different external ID than before.

If WebPQ is configured to require acceptance of the current privacy policy, the user is taken to the normal application startup first, but the application remains blocked by a consent dialog until the privacy policy is accepted. If the user declines, WebPQ logs the user out again.

6.17.5.2. OAuth Configuration

Unlike LDAP, OAuth integration is not configured through the WebPQ user interface. Instead, it must be configured by manually editing the settings.json file.

Where to find the settings.json file:

The location of the settings.json file depends on your installation. You can find the path in the WebPQ administrative backend under Other (see Installation - Part 6). Typical locations include:

To enable OAuth, add or modify the oauth section within the settings.json file. After making changes, restart the WebPQ service for the new configuration to take effect.

Example configuration:

{
    "oauth": {
        "clientId": "your-client-id",
        "clientSecret": "your-client-secret",
        "scope": "openid profile email",
        "discoveryUrl": "https://your-provider.com/.well-known/openid-configuration"
    }
}

6.17.5.3. OAuth Settings Reference

The following settings are available in the oauth section of settings.json:

Required Settings

Server Discovery

You must configure either a discoveryUrl or the server property, but not both.

User Field Mapping

These settings control how user information from the OAuth provider is mapped to WebPQ user properties. The values refer to field names in the response returned by the OAuth provider's userinfo endpoint.

Tip: If you are unsure which fields your OAuth provider returns, enable the debug option (see Advanced Settings below). This will log the full userinfo response from the OAuth server to the authentication log, including all available fields and their values, making it easy to identify the correct field names for the mapping above. Search for the log message containing [OAUTH Debug] Retrieved user info to find the relevant log entry.

Behavior Settings

Advanced Settings

6.17.5.4. Debug Log Location

The debug log messages are located in the logs folder at %PROGRAMDATA%\aeberle\logs\. If the audit log feature has been enabled, the log messages are found in the audit subfolder. Otherwise, they are written to the main log file, where they are prefixed with auth-logger.

Example log output:

[master-data-auth-logger][2026-03-25T22:02:58.987Z][INFO] [OAUTH Debug] Starting OAuth authentication flow
[master-data-auth-logger][2026-03-25T22:02:59.113Z][INFO] [OAUTH Debug] Parsed OAuth server configuration: {
  "token_endpoint": "https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/oauth2/v2.0/token",
  "token_endpoint_auth_methods_supported": [
    "client_secret_post",
    "private_key_jwt",
    "client_secret_basic",
    "self_signed_tls_client_auth"
  ],
  "jwks_uri": "https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/discovery/v2.0/keys",
  "response_modes_supported": [
    "query",
    "fragment",
    "form_post"
  ],
  "subject_types_supported": [
    "pairwise"
  ],
  "id_token_signing_alg_values_supported": [
    "RS256"
  ],
  "response_types_supported": [
    "code",
    "id_token",
    "code id_token",
    "id_token token"
  ],
  "scopes_supported": [
    "openid",
    "profile",
    "email",
    "offline_access"
  ],
  "issuer": "https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/v2.0",
  "request_uri_parameter_supported": false,
  "userinfo_endpoint": "https://graph.microsoft.com/oidc/userinfo",
  "authorization_endpoint": "https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/oauth2/v2.0/authorize",
  "device_authorization_endpoint": "https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/oauth2/v2.0/devicecode",
  "http_logout_supported": true,
  "frontchannel_logout_supported": true,
  "end_session_endpoint": "https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/oauth2/v2.0/logout",
  "claims_supported": [
    "sub",
    "iss",
    "cloud_instance_name",
    "cloud_instance_host_name",
    "cloud_graph_host_name",
    "msgraph_host",
    "aud",
    "exp",
    "iat",
    "auth_time",
    "acr",
    "nonce",
    "preferred_username",
    "name",
    "tid",
    "ver",
    "at_hash",
    "c_hash",
    "email"
  ],
  "kerberos_endpoint": "https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/kerberos",
  "mtls_endpoint_aliases": {
    "token_endpoint": "https://mtlsauth.microsoft.com/12345678-1234-1234-1234-123456789012/oauth2/v2.0/token"
  },
  "tls_client_certificate_bound_access_tokens": true,
  "tenant_region_scope": "EU",
  "cloud_instance_name": "microsoftonline.com",
  "cloud_graph_host_name": "graph.windows.net",
  "msgraph_host": "graph.microsoft.com",
  "rbac_url": "https://pas.windows.net"
}
[master-data-auth-logger][2026-03-25T22:02:59.115Z][INFO] [OAUTH Debug] Using OAuth parameters: {
  "redirect_uri": "https://my-webpq.example.com/authenticate/oauth/callback",
  "scope": "openid profile email",
  "code_challenge": "...",
  "code_challenge_method": "S256",
  "state": "..."
}
[master-data-auth-logger][2026-03-25T22:02:59.122Z][INFO] [OAUTH Debug] Redirecting user to URL: https://login.microsoftonline.com/12345678-1234-1234-1234-123456789012/oauth2/v2.0/authorize?redirect_uri=https%3A%2F%2Fmy-webpq.example.com%2Fauthenticate%2Foauth%2Fcallback&scope=openid+profile+email&code_challenge=...&code_challenge_method=S256&state=...&client_id=...&response_type=code
[master-data-auth-logger][2026-03-25T22:02:59.122Z][INFO] [OAUTH Debug] Saving OAuth session data to cookie: {
  "codeVerifier": "...",
  "state": "...",
  "redirectPath": "https://my-webpq.example.com/"
}
[master-data-auth-logger][2026-03-25T22:03:09.869Z][INFO] [OAUTH Debug] Starting OAuth callback
[master-data-auth-logger][2026-03-25T22:03:09.870Z][INFO] [OAUTH Debug] Parsed OAuth session data from cookie: {
  "codeVerifier": "...",
  "state": "...",
  "redirectPath": "https://my-webpq.example.com/"
}
[master-data-auth-logger][2026-03-25T22:03:09.870Z][INFO] [OAUTH Debug] Using callback URL to parsed OAuth information: https://my-webpq.example.com/authenticate/oauth/callback?code=...&session_state=...
[master-data-auth-logger][2026-03-25T22:03:10.117Z][INFO] [OAUTH Debug] Retrieved tokens: {
  "token_type": "bearer",
  "scope": "email openid profile",
  "expires_in": 3941,
  "ext_expires_in": 3941,
  "access_token": "...",
  "id_token": "..."
}
[master-data-auth-logger][2026-03-25T22:03:10.346Z][INFO] [OAUTH Debug] Retrieved user info: {
  "sub": "...",
  "name": "...",
  "family_name": "...",
  "given_name": "...",
  "email": "...",
  "picture": "https://graph.microsoft.com/v1.0/me/photo/$value"
}
[master-data-auth-logger][2026-03-25T22:03:10.347Z][INFO] [OAUTH Debug] User ... already exists in local storage, checking external source...
[master-data-auth-logger][2026-03-25T22:03:10.349Z][INFO] [OAUTH Debug] User details changed for ..., updating...
[master-data-auth-logger][2026-03-25T22:03:10.369Z][INFO] [OAUTH Debug] Authenticated with username: ...
[master-data-auth-logger][2026-03-25T22:03:10.372Z][INFO] [OAUTH Debug] Redirecting user to URL: /?oauth-redirect=https%3A%2F%2Fmy-webpq.example.com%2F&oauth-success=1
[master-data-auth-logger-USER][2026-03-25T22:03:11.169Z][INFO] <13>1 2026-03-25T22:03:11.169Z localhost - - 100 - [IP: ...]: User ... logged in successfully

6.17.5.5. Full Configuration Example

Below is a complete example configuration using Microsoft Entra ID (formerly Azure AD) with discovery.

Note: Replace {tenant-id} with your actual Microsoft Entra ID (Azure AD) tenant ID.

{
    "oauth": {
        "clientId": "edd6e596-0da2-46dd-9f6b-1be0b3e9b9c3",
        "clientSecret": "your-client-secret-here",
        "scope": "openid profile email",
        "discoveryUrl": "https://login.microsoftonline.com/{tenant-id}/v2.0/.well-known/openid-configuration",
        "debug": false
    }
}

6.17.5.6. Troubleshooting


6.17.6. Device Tagging

6.17.6.1. Tagging Concept in WebPQ

To provide users with a flexible way to organize and classify devices, the WebPQ software features a universal tagging system.

The concept includes the following core components:

Each tag can be assigned to a category, and each device can receive one or more tags.

Virtual devices can be tagged directly or through bulk assignment like other devices. These tags are used for organization and selection; changing them does not change the member devices whose values are summed.

6.17.6.2. System Tags and System Categories

System tags and system categories depend on the connected device. An example is the system category Firmware, which is specifically used for measuring devices. Each measuring device has a system tag where the firmware version is automatically entered – either at the first contact with the device or after connection.

6.17.6.3. Tagging Settings

The settings for tagging and categories require the permission Change device metadata and are located in the menu Settings >> Device Tagging.

Tagging

6.17.6.4. Adding a New Category

  1. Click on "+ Create new category".

  2. Enter a name for the new category, e.g., "Voltage Level".

  3. Enter a unique description, e.g., "Category for defining the voltage level".

  4. Select the tenant for which the category should be available, e.g., "root".

  5. Assign a color to the category, e.g., "Black".

  6. Optionally enable the assignment constraints (these can only be set while creating the category and become immutable afterwards):

6.17.6.5. Setting a Standardized Hierarchy of Categories – System-wide

In the Categories section, the user can set the system-wide order of the hierarchical listing under #1.

Categories

Procedure:

  1. Click in the field #1 → All available categories will be displayed.

  2. Enter the desired category in the dialog box.

  3. Select the desired category.

  4. Remove unnecessary categories if needed.

Example:

Hierarchy

With these settings, all selection dialogs would be sorted in the following order:

  1. Nominal voltage

  2. Device name

  3. Associated slaves in Modbus master mode

This standardized hierarchy ensures a uniform and logical sorting throughout the application.

6.17.6.6. Adding a New Tag

To add a new tag, follow these steps:

  1. Click on "# Create new tag".

  2. Enter a name for the new tag, for example, "11kV".

  3. Enter a unique description, such as "All devices with nominal voltage 11kV".

  4. Select the tenant for which the tag should be available, for example, "root".

  5. Assign the tag to a category, such as "Voltage Level".

  6. Assign a color to the tag, for example, "Black".

After creating the tag, it can be found in the table and assigned to the corresponding devices by clicking on it. This allows efficient management and classification of devices based on the defined tags.

Tagging System

6.17.6.7. Example: A Unique Device Identifier (e.g. GIS-ID)

A common use case is to give every device a globally unique, machine-readable identifier – for example a GIS-ID – so that an external system can address a measurement point through the REST API without relying on the device name. This is modelled with a dedicated tag category whose assignment constraints guarantee a strict one-to-one relationship between identifier and device.

Step 1 – Create the identifier category

Create a new category as described above, for example "GIS-ID", and enable both assignment constraints:

Together these constraints enforce a one-to-one mapping between an identifier and a device. Note that the constraints can only be set while creating the category and become immutable afterwards.

Category with unique-assignment constraints

Step 2 – Create one tag per device identifier

In the "GIS-ID" category, create one tag for each device identifier, for example "GIS-4711" (or "id-123"). Give each tag a unique name that matches the identifier used in your external system.

Step 3 – Assign the tag to its device

Assign each identifier tag to exactly one device. Because of the constraints from step 1, the software prevents assigning the same identifier to more than one device or assigning more than one identifier from this category to a single device.

Assigning a tag to a device

The identifier is then available through the REST API. The device list returned by the API groups each device's tags by category, so an API client can look up which device corresponds to a given GIS-ID and then query its measurement data. See the developer documentation (menu Documentation >> Developer) for the full REST workflow and runnable code examples.


6.17.7. License Management

The License Management page shows the currently stored WebPQ license and is the central place for updating or reactivating it.

License management overview with license master data, articles, and features

The page is primarily relevant for administrators with permission to manage licenses. Regular users can see the effects of a missing or inactive license, but they cannot complete the licensing steps themselves.

6.17.7.1. License File

WebPQ uses a signed JSON license file that is provided via the A. Eberle licensing process.

The file name typically contains the product, order information, and a timestamp. Keep this file stored safely because it is needed again for updates, renewals, or support cases.

Example:

License-WebPQ Basic-2025-12-10T11_40_43.408Z.json

6.17.7.2. Uploading or Replacing a License

In License Management, a new license file can be loaded via + Add License.

Procedure:

  1. Click Browse and select the new JSON license file.

  2. Confirm the displayed license content.

  3. Store the license in WebPQ.

If the new license belongs to a different license ID than the activation already stored in the system, WebPQ shows a warning before replacing it. This warning means the system must be activated again for the new license.

If the license is updated but keeps the same license ID, the existing activation can remain valid.

If the same license file is loaded again, WebPQ does not change the stored license and shows a message that the license remained unchanged.

6.17.7.3. Activation Workflow

Starting with WebPQ 2.1, the installation must also be activated in addition to storing the license file.

Activation is hardware-bound:

  1. WebPQ generates a LicenseActivationRequest.json file for the current host.

  2. This request is uploaded or pasted into the activation portal at https://activate-license.powerquality.cloud.

  3. The portal returns an activation token or activation file.

  4. That activation token is pasted back into WebPQ, or the activation file is imported there.

The activation request can be copied to the clipboard or saved as a file directly from WebPQ.

If the currently stored activation does not match the host hardware anymore, WebPQ reports a hardware mismatch and requires reactivation.

6.17.7.4. Grace Period and User Experience

After a license has been installed but not yet activated, WebPQ allows a grace period of up to 30 days.

6.17.7.5. Reactivation After Host Changes

The activation is tied to the hardware fingerprint of the host system. If the host is moved, replaced, or changed substantially, the stored activation is no longer valid.

In that case:

  1. Generate a new activation request from WebPQ.

  2. Try to activate it through the activation portal.

  3. If the activation has already been used for the previous hardware, contact A. Eberle support so the activation can be reset.

  4. Repeat the activation process with the reset license.

6.17.7.6. Validity Period and Update Eligibility

WebPQ distinguishes between:

For standard licenses, updates are generally covered for 12 months from purchase. If this update period has expired, the installed software can continue to run, but WebPQ shows a warning that patches and software enhancements are no longer covered.

Administrators can hide this warning temporarily. WebPQ shows it again later after a longer period.

If you want to install a newer version after the update entitlement has expired, you need a renewed license or maintenance extension.

6.17.7.7. License Units

Users and license-relevant devices share the unit quantity stored in the WebPQ license. Each virtual device consumes one ordinary device unit. When no unit remains, WebPQ rejects creating another user or license-relevant device; existing users and devices remain available.

6.17.7.8. SaaS and Infinite Licenses

Some product variants, especially SaaS-oriented licenses, can be issued as infinite licenses. In that case WebPQ stores the license without a calendar expiration date.

For users, this means:

6.17.7.9. What Happens During Updates

If an update requires a renewed or different license, load the new JSON license first or during the update process.

If the new license uses a different license ID than the previous one, expect WebPQ to request a fresh activation after the replacement.

For the installation-side activation flow, see the installation chapter.

6.17.7.10. Practical Notes for Support Cases


6.17.8. Data Protection

6.17.8.1. Overview and General Information

In the data protection settings, it is possible to store company-specific data protection policies in the software.

The software offers multilingual templates to document the exact circumstances of data storage and processing in the system.

Data protection settings with language selector, editor, and save action

Users can edit the data protection policies in multiple languages directly in the editor and save them in the system.

After saving, the updated data protection agreement is automatically applied as the default.
It is visible both in the login area and in the footer of the software.


7. Knowledge Base / FAQ

7.1. Working with the Browser

7.1.1. Troubleshooting Connection Issues

The WebPQ application typically loads a large amount of data to provide a comprehensive and detailed display of the content. However, if an error occurs, such as when the connection to the server is interrupted, the browser may not be able to load further data. In such a case, it can be helpful to press the F5 key or the CTRL + R key combination. This will reload the webpage and send a new request to the server, restoring the data connection and reloading the content.

7.1.2. Recommended Browser Settings

7.1.2.1. Caching

To ensure smooth operation in the browser, cookies should be allowed on the PC being used. The cache should be persistently stored at least for the "WebPQ" application. The WebPQ application stores metadata and customer-specific settings, such as those of the "Analysis Cockpit," locally in the "local storage." This prevents unnecessary data transfers from the server to the client and enables quick analyses. If cookies are deleted after leaving the browser, settings are not persisted and may need to be reconfigured. To prevent this, we recommend setting exceptions in the browser for the application.

Procedure (example using the "Firefox" browser):

  1. Open the settings in the browser

  2. Go to the "Privacy & Security" settings

If the checkbox "Delete cookies and site data when Firefox is closed" is checked, the "local storage" will be deleted when the browser is closed, and the above-mentioned case may occur. It is recommended to add an exception for the application (domain).


7.2. WebPQ Service

The WebPQ service can be started via the command line with the --console extension. This option displays all log outputs directly in the console instead of being saved in a separate log file. This can be particularly useful for monitoring errors or important system messages in real-time and quickly responding to issues. Administrators or developers can immediately see which processes are running in the background and intervene if necessary.

7.3. Logfiles

The WebPQ application logs all events of the various processes by default in the directory specified in the WebPQ backend.

7.3.1. Location of logfiles

By default, the log directory can be found under Windows here:
C:\ProgramData\aeberle\webpq\logs

7.3.2. Types of logfiles

WebPQ distinguishes the following log types:

These audit logs serve traceability and security by documenting all relevant changes and activities in the system.

7.3.3. Reading the logfiles

To also access the logfiles on the client, there is an option in the "Syslog" section to download all logfiles from the system.

By clicking the "Download Logfiles" button, all logfiles can be downloaded directly from the system. Additionally, a special logfile with user-specific information can be downloaded via the "Download Audit Logfiles" button.

The availability of the "Download Audit Logfiles" button depends on the user rights. Depending on the permission, the button may be shown or hidden.
Note

7.3.4. Configuration in the settings.json

The following settings are configured in the settings.json file and affect logfiles, data retention, and other system properties.

7.3.4.1. Logfile retention period

To limit the number of stored logfiles, a maximum retention period in days can be defined for logging.

The settings for the logfile retention period are located in the settings.json file. By default, general logfiles are stored for 50 days and audit logfiles for 365 days.

The relevant parameter for limiting is:

"pruneLogsAfterDays": 50

"pruneAuditLogsAfterDays": 365

The WebPQ service must be restarted once on the server to activate the setting.

7.3.4.2. Automatic deletion of older measurement data per data class

WebPQ can control the retention of measurement data differently for each data class. The configuration is stored in the settings.json file through dedicated entries per data class. This makes it possible to define whether older data of a data class is deleted automatically and after how many days this happens.

The two most important settings are:

If pruneEnabled is set to false, no regular automatic deletion is intended for this data class by default. In that case, a high value such as 9125 is not a typical active retention period but a technical configuration value.

If automatic deletion is enabled for a data class, WebPQ removes the oldest data of that data class first. Newer data remains available. For users, this means that the available history is limited to the configured retention period, while current measurement data remains available. This follows the FIFO principle, First In, First Out: the oldest stored data leaves the data set first.

Short retention periods reduce storage usage, but they also limit the historical depth available for analyses, exports, and reports. Data classes with automatic deletion disabled remain available long-term by default.

Evaluations according to IEEE standards often require the 3-second data (c3s) to be available and analysed. Because this data class is deleted automatically after 60 days by default, the settings.json must be adjusted in any case if such standards-based evaluations need to remain possible over longer periods.

The following table shows the default values of the data-class configuration stored in the system. The first column intentionally uses the technical data-class keys from the settings.json. The description additionally explains the user-facing application terms behind them, for example OSC recorder and TRMS recorder:

Data classAutomatic deletion enabledDefault retention periodMeaning for the user
c3sYes60 daysShort-cycle 3-second values are deleted after 60 days by default.
c1sYes60 daysShort-cycle 1-second values are deleted after 60 days by default.
c200msYes30 daysVery high-resolution 200 ms values are deleted after 30 days by default.
ceventNo9125 daysEvent data is not intended for regular automatic deletion by default.
c2hNo9125 days2-hour values remain available long-term by default.
c10mNo9125 days10-minute values remain available long-term by default.
c10sNo9125 days10-second values remain available long-term by default.
cdayNo9125 daysDaily values remain available long-term by default.
binaryNo9125 daysBinary data remains available long-term by default.
crecaNo9125 daysData of the OSC recorder remains available long-term by default.
crecbNo9125 daysData of the TRMS recorder remains available long-term by default.
creccNo9125 daysData of the harmonics recorder remains available long-term by default.
crecsNo9125 daysData of the ripple-control recorder remains available long-term by default.
cmbmasterNo9125 daysModbus master communication data remains available long-term by default.
cnmNo9125 daysThis data class remains available long-term by default.
cnsNo9125 daysThis data class remains available long-term by default.
rmsonlnNo9125 daysOnline RMS data remains available long-term by default.

7.3.4.3. Embedding in an iframe

By default, WebPQ sends additional HTTP security headers that prevent the application from being embedded in a third-party iframe. This is the secure default and primarily protects against clickjacking.

For special on-premise scenarios, embedding can be adjusted through the settings.json file if required.

The relevant parameter is:

"allowEmbeddingInIframe": false | "same-origin" | true

Example in the settings.json file:

"http": {
  "httpAccessLogging": false,
  "allowEmbeddingInIframe": "same-origin"
}

Notes:

7.3.4.4. HTTP Strict Transport Security HSTS

WebPQ can additionally send the Strict-Transport-Security header. This instructs browsers to keep using HTTPS for the application for a longer period after the header has been received once.

The relevant parameter is:

"strictTransportSecurity": true

Example in the settings.json file:

"reverseProxy": {
  "https": {
    "strictTransportSecurity": true
  }
},
"http": {
  "httpAccessLogging": false,
  "allowEmbeddingInIframe": false
}

Notes:


7.4. Manual move of a system from A to B

This section describes the manual migration of an existing WebPQ installation from a source system A to a target system B.

The guide is intended for on-premise Windows installations when the migration should be performed in a controlled step-by-step way.

7.4.1. WebPQ Migration Tool (recommended)

WebPQ ships with a migration tool that automates the backup, transport, and restore of a local installation. It is the recommended way to move a system from A to B or to create a transportable backup. The manual step-by-step guide further below is a fallback for controlled migrations or for environments in which the tool cannot be used.

You can use the tool in two ways:

What the modes do:

Please note:

Using the command line (without the Admin UI)

Every function of the Admin UI is also available from the command line through scripts\WebPqMigrationTool.cmd (a thin wrapper around WebPqMigrationTool.ps1). This is the way to run scripted or unattended backups and to schedule a recurring backup without the Admin UI. Open the command prompt as Administrator for Backup and Restore.

Examples (command prompt started as Administrator):

REM Check readiness without changing anything (paths, services, disk space, non-automatable items)
WebPqMigrationTool.cmd -Mode Preflight -TargetPath "D:\Backups\WebPQ"

REM List what would be backed up (the entry names for -SelectedEntries), without backing up
WebPqMigrationTool.cmd -Mode Discover

REM Full backup into a timestamped folder WebPqBackup_<UTC>
WebPqMigrationTool.cmd -Mode Backup -TargetPath "D:\Backups\WebPQ"

REM Full backup as a single transportable (unencrypted) .zip
WebPqMigrationTool.cmd -Mode Backup -TargetPath "D:\Backups\WebPQ" -CreateZip

REM Restore into a staging folder to inspect it safely (the live installation is not touched)
WebPqMigrationTool.cmd -Mode Restore -SourcePath "D:\Backups\WebPQ\WebPqBackup_20260706-020000Z" -TargetPath "D:\Staging\WebPQ"

REM Restore an unencrypted portable-secrets backup onto the original paths
WebPqMigrationTool.cmd -Mode Restore -SourcePath "D:\Backups\WebPQ\WebPqBackup_20260706-020000Z" -RestartServices

REM Restore a password-protected portable-secrets backup; delete the password file afterwards
WebPqMigrationTool.cmd -Mode Restore -SourcePath "D:\Backups\WebPQ\WebPqBackup_20260706-020000Z" -RestartServices -BackupPasswordFile "C:\temp\webpq-backup-password.txt"

The most useful parameters:

ParameterApplies toMeaning
-ModeallDiscover, Preflight, Backup, or Restore.
-TargetPathBackup, RestoreBackup: destination folder. Restore: staging folder (omit it to restore onto the original paths).
-SourcePathRestoreThe backup folder or .zip to restore from.
-CreateZipBackupPack the backup into a single (unencrypted) .zip. Needs roughly twice the space during packing.
-SelectedEntriesBackupComma-separated entry names from -Mode Discover. Omitted = back up everything; settings is always included.
-SettingsPathallPath to settings.json. Default C:\ProgramData\aeberle\webpq\settings.json.
-DatabaseDataPathBackup, RestoreOverride the PostgreSQL data directory if it is not at the default location.
-WebPqServiceName / -DatabaseServiceNameallOverride the service names if your installation differs from WebPQService / WebPQDatabase.
-BackupPasswordFileRestorePath to the password for a password-protected portable-secrets.json. Prefer this over putting a password on a command line and delete the file afterwards.
-MasterEncryptionKey / -MasterDbPassword / -MeasureDbPassword / -KvsPassword / -HttpsPassPhraseRestoreOverride individual secrets. A value given here wins over the one stored in the backup, so use it to restore with a deliberately different value (or when no usable portable-secrets.json is available).
-RestoreSecretsFileRestoreJSON file containing the same manual overrides. Prefer it to passwords on the command line and delete it afterwards.
-RestartServicesRestoreRestart the services after an original-path restore.
-FolderPathMapRestoreRedirect folders on an original-path restore to a different drive layout, e.g. `-FolderPathMap "longTermDataFolder=E:\WebPQ\ltmapsFolder=E:\WebPQ\maps"`.
-UnattendedBackupTreat a disk-space shortfall as a hard error (recorded in the status file) instead of a warning. Use it for scheduled runs where nobody is present to confirm.

Before it stops any service, a backup estimates the space it needs (dominated by the database size) and compares it with the free space on the target. Interactively this is a warning you can override; with -Unattended the run aborts and writes the reason into the status file, so a scheduled backup never leaves the services stopped with a half-written result.

Scheduling a recurring backup without the Admin UI

The Admin UI's "daily automated backup" simply creates a Windows Task Scheduler task that runs the backup command above as the SYSTEM account. You can create the same task by hand — for example a daily backup at 02:00 — from a command prompt started as Administrator:

schtasks /Create /TN "WebPQ Automated Backup" /RU SYSTEM /RL HIGHEST /SC DAILY /ST 02:00 /F /TR "\"C:\Program Files\WebPQ\resources\scripts\WebPqMigrationTool.cmd\" -Mode Backup -TargetPath \"D:\Backups\WebPQ\" -CreateZip -Unattended"

Please note:

Clarify these points before the move

Before the actual migration starts, at least the following points should be clear:

Typical default values are:

If services are stopped or started from the Windows command prompt, the cmd window must be opened as Administrator.

Step 1: Identify system A

  1. Identify the active settings.json on system A.

  2. List all relevant folders referenced from settings.json.

  3. Check whether WebPQDatabase exists locally or whether an external database is used.

  4. Make all passwords from system A available for later entry on system B (see step 6).

Step 2: Stop the services on system A

  1. Stop WebPQService.

  2. If present locally, stop WebPQDatabase.

  3. Make sure that no other process is still writing into the folders that will be copied.

Example in a Windows command prompt started as Administrator:

net stop WebPQService
net stop WebPQDatabase

This helps avoid copying an inconsistent system state.

Step 3: Back up the data from system A

The following content should be copied 1:1:

A clearly structured transfer folder or ZIP package is recommended so that nothing is missed on system B.

Step 4: Prepare system B

  1. Install WebPQ on system B.

  2. Verify that the required services exist on system B.

  3. Stop existing WebPQ services on system B.

  4. Ensure that sufficient permissions and free disk space are available on the target paths.

Example in a Windows command prompt started as Administrator:

net stop WebPQService
net stop WebPQDatabase

Step 5: Copy the data to system B

  1. Copy the backed-up settings.json to the intended location on system B.

  2. Copy the backed-up WebPQ folders to their target locations.

  3. If the database is local, copy the PostgreSQL data folder to the database path on system B.

If the folder structure differs on system B, the path entries in settings.json must be adjusted accordingly.

Step 6: Set the passwords on system B

Every password in settings.json is encrypted for the Windows account and the machine of system A and cannot be read on system B. Each of them has to be entered as plain text:

Entry in settings.jsonContent
masterEncryptionKeyMaster Encryption Key
masterDB.passMaster database password
measureDB.passMeasurement database password
kvs.passKey-value store password
reverseProxy.https.passPhraseHTTPS private key passphrase

Enter each value as plain and remove any encrypted and verifier of the same entry while doing so:

{
  "masterEncryptionKey": {
    "plain": "<value from system A>"
  }
}

WebPQ re-encrypts these values for system B on its first start. Without this step WebPQ does not start but repeatedly reports a decryption error for settings.json.

Step 7: Check additional topics

Before the first startup on system B, also verify:

Step 8: Start the services on system B

  1. If present locally, start WebPQDatabase first.

  2. Then start WebPQService.

  3. Test the basic availability and functionality of WebPQ.

Example in a Windows command prompt started as Administrator:

net start WebPQDatabase
net start WebPQService

Step 9: Verify the system after the move

After starting system B, at least the following checks should be performed:

Typical issues after the move

WebPQ does not start and reports a decryption error for settings.json

The log repeatedly shows Settings file … has a problem: … cannot decrypt the settings value "…" or Error while decrypting the ciphertext provided to safeStorage.decryptString. In that case settings.json was taken over unchanged and its encrypted passwords cannot be read on system B. Perform step 6 for all five values and restart the services. The automatic recovery of the admin interface does not help here — it is meant for a context change on the same machine, not for a change of machine.

The Master Encryption Key was not transferred

In this case, some data on system B cannot be decrypted correctly.

The database data was not moved

In this case, the application may start, but historical data is missing.

The paths in settings.json do not match system B

In this case, data folders, export paths, or other content cannot be found.

Certificates or keys are missing

In this case, encrypted connections or external integrations may fail after the migration.

7.5. Backup and Restore

7.5.1. Overview of Backup Options

In practice, there are three useful backup strategies for WebPQ. The right option mainly depends on whether the installation is intended to be simple or highly resilient.

7.5.1.1. Option 1: Full backup of the complete virtual machine

This option is especially suitable for simple installations where the WebPQ application is installed on drive C: and the database is installed on drive D: of the same virtual machine.

In this setup, the complete virtual machine is backed up including all attached disks. This means the backup contains the operating system, the WebPQ installation, configuration, user data, certificates, and the database on drive D: together.

Advantages:

Notes:

7.5.1.2. Option 2: Machine backup plus separate database backup

For many production systems, this is the recommended standard approach. In this model, the machine or virtual machine is backed up and the database is additionally protected by its own database backup concept.

The advantage is that the system environment and the database can be restored separately. This makes it possible, for example, to restore a server to a known-good state while recovering the database from a newer or specifically selected backup point.

This concept usually includes:

This option is usually more robust than relying on a machine backup alone because logical database errors or accidental changes can be corrected more precisely.

7.5.1.3. Option 3: Advanced concept with database mirror and classic backups

For installations with higher availability requirements and short downtime targets, an advanced concept with an additional PostgreSQL backup mirror via streaming replication and complementary classic backups is recommended.

In this model, the existing backup mirror is operated as a continuously updated copy of the production database. In an emergency, the backup server can be promoted to the new primary server. The setup details are described in the installation chapter under PostgreSQL Backup Mirror with Streaming Replication.

The important point is:

This option is the best basis when restoration should be possible within a few hours or faster.

7.5.1.4. Position of existing WinPQ backups

An existing automatic backup via WinPQ can still be useful, especially for device parameters or device-specific configurations. However, it should not be treated as the only strategy for the complete restoration of a WebPQ system.

For full restoration, at least the server or VM backup, the database backup, and the backup of relevant configuration and key material are also required.

7.5.2. Restore Path and Recommended Approach

Fast and complete restoration requires not only a backup itself but also a clear restore procedure.

The recommended approach is:

  1. Choose a backup strategy that allows the operating system, the WebPQ application, the database, and the configuration data to be restored together or in a coordinated way.

  2. Ensure that certificates, license information, passwords, connection data, and exported keys are stored securely in addition to the database contents.

  3. Perform test restores regularly so that no unknown steps remain in a real emergency.

  4. Store backups outside the productive server or datacenter so that they remain available even in the event of hardware failure or site damage.

Depending on the selected strategy, the typical restore path is as follows:

For minimum downtime, option 3 is usually the best choice. For smaller or simpler installations, option 2 is usually the best compromise between effort, safety, and recovery time. Option 1 is practical for simple single-server installations, provided that all relevant disks and configuration data are really included in the VM backup.


7.6. Information about the SSL Certificate of the WebPQ Web Server

The application you are using requires certificates and keys in PEM format (Privacy-Enhanced Mail). PEM is a standardized format for storing and transmitting cryptographic data, such as certificates, private keys, and public keys.

What is the PEM format?

The PEM format is a text format that encodes cryptographic data and represents it as Base64-encoded strings. These data are surrounded by "Begin" and "End" markers to denote the different types of cryptographic information.

Example:

A certificate in PEM format looks like this:

-----BEGIN CERTIFICATE----- MIIDdzCCAl+gAwIBAgIEU1mW... ...klrjDffKwF2MnPxgt1h0DA== -----END CERTIFICATE-----

A private key in PEM format looks like this:

-----BEGIN PRIVATE KEY----- MIIEvgIBADANBgkqhkiG9w0BAQEFAASCBKgwggSkAgEAAoIBAQ... ...jJTZMOyPyjxVrM52mf6w== -----END PRIVATE KEY-----

Why PEM?

The PEM format is often used because it is easily readable and simple to handle. It allows for easy storage of certificates and keys in a text file that can be used in various applications and servers. How to use certificates and keys in PEM format?

Encryption:

If the key in PEM format is encrypted, a password can be entered in the application to decrypt and use the key.

Example:

An encrypted private key in PEM format might look like this:

-----BEGIN ENCRYPTED PRIVATE KEY----- MIIEpAIBAAKCAQEA7JzQ+opZX7bPmnB6BBQ5mQgCvZvXq4bD8+Gm3kmK2b7HLkn7 ... -----END ENCRYPTED PRIVATE KEY-----

In this case, the private key is encrypted with a passphrase. When someone tries to access this key, they will be prompted to enter the passphrase to enable decryption.

Common Issues:

If you have any further questions regarding certificates or keys in PEM format, please contact support.


8. Updates

The WebPQ software is continuously developed. Within the license period of 12 months, updates are free of charge and can be downloaded directly from the homepage
www.a-eberle.de.

It is recommended to always install the latest version to close security gaps and take advantage of new features. For patch management, A. Eberle GmbH provides a customer portal:
https://www.a-eberle.de/news/anmeldung-kundenportal/

8.1. Installation of the Update

The update can be installed directly via the installation routine. Administrative rights are required for this.

8.1.1. WebPQ Update

To install the update, proceed as follows:

If the update entitlement of the currently stored license has expired, the installed system can still continue to run, but newer updates require a renewed license or maintenance extension.

If the installer or the running system requests a new license, load the renewed JSON license and complete activation again if WebPQ asks for it.

Back up your database before each update to avoid data loss!
Note

8.1.2. Database Backup

If the database is operated via PostgreSQL, you can back up the database as follows:

A continuously updated PostgreSQL backup mirror using streaming replication can increase resilience further. However, this replication does not replace a classic backup before updates. For production systems, it is recommended to combine a replication server with additional regular database backups. An example setup of the backup mirror is described in the installation chapter under PostgreSQL Backup Mirror with Streaming Replication.

8.2. Support in Case of Service Issues

If you have problems or questions, please contact A. Eberle Support:

Service Address:

A. Eberle GmbH & Co KG
Frankenstraße 160
D-90461 Nuremberg

Regular updates ensure the security and optimal performance of the software.


9. Product Warranty

A. Eberle guarantees that this product will remain updatable for a period of 12 months from the date of purchase.

The warranty does not cover damages caused by the following:

To claim the warranty, please contact A. Eberle GmbH & Co. KG in Nuremberg.

A. Eberle GmbH & Co. KG Frankenstraße 160
D-90461 Nuremberg
Tel.: +49 (0) 911 / 62 81 08-0 Fax: +49 (0) 911 / 62 81 08 99
E-Mail: info@a-eberle.de

www.a-eberle.de


10. Release Notes

WebPQ displayed on smartphone, desktop monitor, and laptop

Note: The following pages contain the release notes for the WebPQ software and the REST API. Please note that these release notes may not always reflect the current state of the software version. With software updates, it may happen that the present description is no longer accurate in some points. In this case, please contact us directly or use the latest version of the release notes, which you can find on our website www.a-eberle.de.

Publisher: A. Eberle GmbH & Co. KG Frankenstraße 160 D-90461 Nürnberg


10.1. WebPQ Releases

10.1.1. Recommended Device Firmware

Device TypeDSP / HardwareInputsFirmware Version / DateNotes
PQI-D(A)DSP 100 MHz8 voltage inputs2.1.03 (02.06.2021)
PQI-D(A)DSP 100 MHz4 current, 4 voltage3.1.01 (07.05.2014)
PQI-D(A)DSP 200 MHz8 voltage inputs4.0.07 (10.05.2011)
PQI-D(A)DSP 200 MHz4 current, 4 voltage5.0.16 (09.04.2014)
PQI-D(A)DSP 300 MHz4 current, 4 voltage7.0.04 (07.07.2015)
PQI-DA smartGen 1, 2, 34 current, 4 voltage>= 3.4.4Web server enabled
PQI-DEGen 1, 2, 34 current, 4 voltage>= 3.4.4Web server enabled
PQI-LVGen 1, 2, 34 current, 4 voltage>= 3.4.4Web server enabled

10.1.2. Database Patches

Patches for the deployed PostgreSQL database are provided via a separate update process. You can find the latest patches in the download center under "WinPQ" in the "PostgreSQL Patches" section, as well as in the program directory under /PostgreSQL Update/ in the update folder of the WebPQ installation. The full version of the WebPQ system software always includes the latest database version available at the time of release.

Starting with this update, it is recommended to use PostgreSQL v18.6.


10.1.3. WebPQ 2.3.1

News, Features, and Improvements

Security-related content and adjustments


10.1.4. WebPQ 2.3.0

Release highlights

WebPQ 2.3.0 expands analysis across measuring points and automates recurring import and reporting tasks.

News, Features, and Improvements

Security-related content and adjustments


10.1.5. WebPQ 2.2.8

News, Features, and Improvements

Security-related content and adjustments


10.1.6. WebPQ 2.2.7

News, Features, and Improvements

Security-related content and adjustments

The following security updates were applied as a precaution; no direct product impact is known.


10.1.7. WebPQ 2.2.6

News, Features, and Improvements


10.1.8. WebPQ 2.2.5

News, Features, and Improvements


10.1.9. WebPQ 2.2.4

News, Features, and Improvements

Security-related content and adjustments

The following security updates were applied as a precaution; no direct product impact is known.


10.1.10. WebPQ 2.2.3

News, Features, and Improvements

Security-related content and adjustments

The following security updates were applied as a precaution; no direct product impact is known.


10.1.11. WebPQ 2.2.2

News, Features, and Improvements


10.1.12. WebPQ 2.2.1

News, Features, and Improvements

Security-related content and adjustments


10.1.13. WebPQ 2.2.0 - Major Release

Primary Tracking Ticket / Topic Reference

News, Features, and Improvements

Additional Important Enhancements

Important Bug Fixes

Security-related Content and Adjustments

Applicable or release-relevant security issues:

Not applicable or not release-relevant security issues:

10.1.14. WebPQ 2.1.8

Security-related content and adjustments

Non -critical security issues fixed in this release:

10.1.15. WebPQ 2.1.7

News, Features, and Improvements

Security-related content and adjustments

Non-critical security issues fixed in this release:


10.1.16. WebPQ 2.1.6

News, Features, and Improvements


10.1.17. WebPQ 2.1.5

Security-related content and adjustments


10.1.18. WebPQ 2.1.4

News, Features, and Improvements

Security-related content and adjustments

All None critical security issues have been fixed in this release:


10.1.19. WebPQ 2.1.3

News, Features, and Improvements


10.1.20. WebPQ 2.1.2

News, Features, and Improvements

Security-related content and adjustments


10.1.21. WebPQ 2.1.0 - Major Release

News, Features, and Improvements

Security-related Content and Adjustments


10.1.22. WebPQ 2.0.11

News, Features, and Improvements

10.1.23. WebPQ 2.0.10

News, Features, and Improvements

Security-related content and adjustments

10.1.24. WebPQ 2.0.9

News, Features, and Improvements

10.1.25. WebPQ 2.0.8

News, Features, and Improvements

10.1.26. WebPQ 2.0.7

News, Features, and Improvements

Security-related content and adjustments


10.1.27. WebPQ 2.0.6

News, Features, and Improvements

10.1.28. WebPQ 2.0.5

News, Features, and Improvements

Security-related content and adjustments


10.1.29. WebPQ 2.0.4

News, Features, and Improvements

=======

10.1.30. WebPQ 2.0.3

News, Features, and Improvements


10.1.31. WebPQ 2.0.2

News, Features, and Improvements

Security-related content and adjustments

10.1.32. WebPQ 2.0.1

News, Features, and Improvements

Security-related content and adjustments

10.2. REST API Versions

10.2.1. REST API v 2.0.0

API Changes

The API has been restricted to its public part and adapted to a versioning scheme. As a result, the endpoint paths have changed. See below for each endpoint.

Most endpoints that previously supported POST and GET have been mostly restricted to POST. The endpoints that query measurement data have been changed regarding the start/end dates. The start dates are now exclusive, the end dates are inclusive.

Most error responses now add a 'subCode' field that contains a general problem description such as 'NOT_AUTHORIZED' or 'INVALID_PARAMETER'. This field can be easily checked by the API client to respond accordingly.

Changes per API Endpoint

/analytics/rawtimeseries -> /api/v1/analytics/rawtimeseries

/analytics/recordings -> /api/v1/analytics/recordings

/analytics/getpqevents -> /api/v1/analytics/getpqevents

/analytics/version -> /api/version

/authenticate/user -> /api/v1/authenticate/user

/master-data/user/getuser -> /api/v1/device/getdevices


Version: 2.3.1 | Build date: 2026-10-19T11:12:15.555Z